Prostat PAN-750 User Manual Download Page 1

User Manual

PAN-750

ANEMOMETER

Summary of Contents for PAN-750

Page 1: ...User Manual PAN 750 ANEMOMETER ...

Page 2: ......

Page 3: ... Replacement 7 VIII Features 7 General Specifications 9 Table of Contents Copyright 2011 by Prostat Corporation All rights reserved Printed in the United States of America No part of this manual may be used or reproduced in any manner whatsoever without written permission For information contact Prostat Corporation 1072 Tower Lane Bensenville IL 60106 USA Prostat is the registered trademark of Pro...

Page 4: ...ity will display simultaneously D Press the Unit key The display will show the unit of m s km h ft min knots or mile hr These are as follows m s meters per second ft min feet per minute mile h miles per hour km h kilometer per hour knots nautical miles per hour international knot The units printed on the keypad under the unit button DO correspond to the units on the display however the sequence of...

Page 5: ...e LCD display IV Obtaining a Measurement A Measuring an Ionizer 1 Install the Sensor Plug into the Sensor Input Socket as previously described 2 The flat arrow side of the sensor input socket faces down and the arrow points towards the PAN 750 when installing 3 If the sensor input socket does not easily slide into the sensor plug look at the direction of the arrow and try again DO NOT FORCE THE IN...

Page 6: ...e ionizer on for 30 minutes to warm up prior to attempting to measure the ionizer air flow 1 The heater should be OFF if the ionizer to be measured is so equipped 2 All filters should be in place is the ionizer is so equipped F Hold the sensor head vane parallel to and in the center of the ionizer stream 1 The side of the vane with the yellow dot should be facing the ionizer 2 Position the vane ap...

Page 7: ...LBT display an in spec measurement may still be made for several hours after the low battery indicator appears before the instrument becomes inaccurate 1 To replace the battery remove the unit from the rubber holster 2 Pry the Battery Cover open with a coin or screwdriver and remove the battery 3 Replace with a 9V battery heavy duty type and re place the battery cover 4 Make sure the battery cover...

Page 8: ... 80 RH H Power Supply 9V battery Heavy Duty Type I Power Current Approximately DC 8 3 mA J Weight 381 g 0 84 lb includes battery and probe CAUTION DO NOT IMMERSE PROBE INTO LIQUIDS IMMERSING IN LIQUIDS WILL CAUSE PERMANENT DAMAGE TO THE SENSOR 8 Rev B July 2001 PAN 750 Anemometer ...

Page 9: ...and Maximum measurement recall Controls DATA HOLD button Recall MIN MAX button C F button Resolution Temperature resolution in 10th s of a degree Relative Humidity in 1 increments Response Time Approximately 80 Seconds Auto OFF Automatic power off after 20 minutes to prevent battery drains when not in use Size 1 9 inches wide x 6 7 inches long x 0 5 inch deep Accuracy Temperature 1 C 1 8 F Humidit...

Page 10: ...NOTES 10 Rev B July 2001 PAN 750 Anemometer ...

Page 11: ......

Page 12: ...Prostat Corporation All other trademarks and trade names are the property of their respective companies P R O F E S S I O N A L S T A T I C C O N T R O L P R O D U C T S Prostat Corporation Corporate Headquarters 1072 Tower Lane Bensenville IL 60106 630 238 8883 Fax 630 238 9717 1 855 STATIC1 www prostatcorp com ...