ProStart CT-3200 Installation Manual Download Page 18

P. 18

  

Installation 

Guide

 CT-3200

 

Solution:  

A relay is used to invert the negative signal from the start module to a positive signal 
before it is sent to the OEM switch. 

The relay connections: 

85:

 

Connects to the start module's Trunk release output wire. This becomes the negative 
side of the coil. 

86: 

 

Connects to a fused +12 Volts source. This becomes the positive side of the coil. 

87

:  

Connects to a fused +12 Volts source. This becomes the supply for the positive trunk 
release. 

87A:

  

No connection. This terminal is not used in this application.  

30

:   

Connects to the OEM trunk wire in the vehicle. 

Comments: 

At rest, the trunk switch is allowed to operate normally. When the Trunk button on the 

remote is pressed, the negative Trunk output from the remote start module triggers the 
relay. When the relay is activated, +12 volts from 87 is sent through 30, and the OEM 
trunk switch is activated, by the positive pulse. 

Interruption: 

Example:

  Creating a Starter Kill relay to prevent unauthorized starting of the vehicle. 

Problem:

  The OEM starter circuit needs to be disabled only when theft is attempted. 

Solution:

  A relay is used to interrupt the OEM starter wire. There is  an output on the remote 

start module especially for this purpose ( Starter Kill output).  

The relay connections: 

85: 

Connects to the Starter Kill output wire from the remote start module. This becomes 
the negative trigger for the coil. 

86:  

Connects to the vehicle's Ignition wire. This becomes the positive trigger for the coil. 

87:  

No connection. This terminal is not used in this application. 

The vehicle's OEM start wire is cut. The side of the wire that is still connected to the Ignition switch 
becomes the “Key Side” of the starter wire. The side of the wire that is still connected to the starter 
motor becomes the “Starter Side” of the of the starter wire.  

87A:

 

Connects to the “Key Side” of the cut OEM starter wire. 

30: 

 

Connects to the “Starter Side” of the cut OEM start wire. 

 

Comments:

 At rest the relay is not active, and +12 volts on the starter wire passes through the 
relay (through 87A & 30) normally. The Starter Kill output wire on the remote start 
module is activated when the LOCK button is pressed on the remote control.  When a 
theft attempt happens, and the thief powers the Ignition circuit (to hot wire the vehicle), 
and the Starter Kill was ARMED (by the LOCK button on the remote) the starter kill 
relay activates. The OEM start wire is now open, (does not make connection) because 
30 is no longer connected to 87A, and the vehicle is unable to start.  

Strengthening current: 

Example

:  Strengthening an output 

Problem:

   A vehicle has a negative (-) trigger Trunk release wire. The module has a negative 

Trunk release output wire. The remote start module is unable to supply the necessary 
current to activate the vehicle's Trunk release wire.  

Solution

:   A Relay is used to provide the necessary negative current to active the vehicle's Trunk 

release wire.  

The relay connections: 

85

Connects to the start module's Trunk release wire output. This becomes the Negative 
trigger for the coil. 

86

Connects to a fused +12 Volt source.  

87

Connects to a Negative source. i.e. The spot where the remote start module is 
grounded. This becomes the supply for activating the vehicle's Trunk release wire.  

87A

No connection. This terminal is not used in this application. 

Summary of Contents for CT-3200

Page 1: ...ed in Canada by Autostart A U T O M A T I C T R A N S M I S S I O N M U L T I C H A N N E L R E M O T E S T A R T E R S Y S T E M CT 3200 Installation Guide Table of Contents Introduction 2 Included i...

Page 2: ...undesired operation of the device To reduce potential radio interference to other users the antenna type and its gain should be so chosen that the equivalent isotropically radiated power EIRP is not...

Page 3: ...rnal relays or modules added to the remote starter module are properly fused and diode isolated when testing the shock sensor never test on glass with an opened hand and never hit glass hard enough as...

Page 4: ...ional ignitions accessories or starter wires must use external relays DO NOT JUMP WIRES at the ignition switch this will compromise the OEM electrical system 5 Pin Secondary Harness Wire Description 1...

Page 5: ...programming menu see page 9 7 WHITE ORANGE Starter Kill Armed output The unit is equipped with a selectable passive or active arming starter kill circuit that will immobilize the vehicle when the sys...

Page 6: ...tiple relays or modules are connected to the ground out wire ensure that they are all diode isolated in order to avoid feedback and damaging the vehicle 11 GREY N A This pin is not used leave empty 12...

Page 7: ...makes the module go into the programming centre Once the module is in the programming centre the installer has no more than 20 seconds to get into one of the sub menus Failure to do so will result in...

Page 8: ...ing into the programming option mode the parking lights will flash once twice depending on the option you have entered The unit will stay in programming mode until the hood pin switch or the brake ped...

Page 9: ...starter kill engages This option should be selected ONLY if the starter kill is installed MODE 2 indicates default setting FUNCTION 1 Engine Run Time OPTION 1 4 minute Run Time in Gas Mode 9 minute in...

Page 10: ...le 5 Testing Before putting back the vehicle together it is recommended to check that the system operates properly The following testing procedures should be used to verify proper installation and ope...

Page 11: ...t uses three sets of pins Each set of ote Only one set of pins can be used at a time ote Only one set of pins can be used at a time pins has a function To activate one of the three possible 2nd output...

Page 12: ...se Duration The Door Lock pulse dur default 4 sec LOCK and UNLOCK pulses or for a 7 10 sec LOCK pulse and two 1 4 second UNLOCK pulses used for double pulse disarm unlock systems In GAS mode the Mod m...

Page 13: ...ting range This includes the metal in the car The shape of the po ge 13 The shape of the roof and A pillars brings about considerable radio frequency deflection in this case th fa relation to the remo...

Page 14: ...market grommet when ever you drill a hole through the fire wall This will protect the wires from rubbing against the bare metal and possibly shorting out If you are installing an Alarm starter combo m...

Page 15: ...all is complete and the vehicle can be put back together A basic introduction to the Relay What is a relay A device that responds to a small current or voltage change by activating switches or other d...

Page 16: ...diode A diode installed between the coil terminals 85 and 86 could be internal or external To activate the coil on this type of relay make sure that the 12 Volts trigger is on the same terminal of th...

Page 17: ...the park light switch and activates the wipers Where the connection was made from the start modules Park light output and the vehicle s park light circuit the OEM park light wire is cut to isolate th...

Page 18: ...vehicle s OEM start wire is cut The side of the wire that is still connected to the Ignition switch becomes the Key Side of the starter wire The side of the wire that is still connected to the starte...

Page 19: ...n relation to the remote control can affect the range Straight on standing in front of the vehicle generally gives you the greatest range the second best performance is from the back Using the remote...

Page 20: ...ake an Auto Tach Adjustment Weak Tach signal Bad ground 7 The car starts by remote but then the starter re engages Check ground wire Is Tach programmed 8 The car starts on it s own Is the module in co...

Page 21: ...ith the key again Does the vehicle have factory alarm keyless entry You might have to switch to a 433MHZ module Some GM Trucks Cavalier Sunfire Breeze Stratus Cirrus 22 Sometimes I have to press butto...

Reviews: