Hardware Specifications
Enclosure
Extruded aluminum with DIN and panel mount
Size
104 ´ 94 ´ 53 mm (W ´ H ´ D)
4.1 ´ 3.7 ´ 2.1 inches
Vibration
IEC 60068-2-6 (20g, 3-Axis)
Shock
IEC 60068-2-27 (5g, 10Hz to 150Hz)
Serial Data Ports (2)
DB9, RS-232
RS-422 and RS-485
300 bps to 230 kbps
Configuration Port
DB9, RS-232
Antenna Ports
(1) RP-SMA connector
Weight
1.0 lbs (454 g)
Environmental
Operating Temperature
–40° C to +75° C
Humidity
Up to 100% RH, without condensation
External Power
10Vdc to 24Vdc
Power Consumption
12 W peak
Agency Approvals & Certifications
UL
ISA 12.12.01 Class I Div 2 Groups A, B, C & D, T5.
Must be installed inside an IP54 enclosure that requires tool
access.
CSA/cUL
C22.2 No. 213-M1987
ATEX Category 3, Zone 2
II 3 G
Ex nA IIC T5 X
-30 C <= Ta <= +60 C