ProSoft Technology InRax PC56 Quick Start Manual Download Page 23

Support, Service & Warranty 

PC56 

 ControlLogix Platform 

Quick Start Guide 

In-Rack Industrial PC 

 

 
ProSoft Technology, Inc. 

Page 23 of 25 

November 18, 2009 
 

2.3.4 Intellectual 

Property 

Indemnity 

Buyer shall indemnify and hold harmless ProSoft and its employees from and 
against all liabilities, losses, claims, costs and expenses (including attorney’s 
fees and expenses) related to any claim, investigation, litigation or proceeding 
(whether or not ProSoft is a party) which arises or is alleged to arise from Buyer’s 
acts or omissions under these Terms or in any way with respect to the Products. 
Without limiting the foregoing, Buyer (at its own expense) shall indemnify and 
hold harmless ProSoft and defend or settle any action brought against such 
Companies to the extent based on a claim that any Product made to Buyer 
specifications infringed intellectual property rights of another party. ProSoft 
makes no warranty that the product is or will be delivered free of any person’s 
claiming of patent, trademark, or similar infringement. The Buyer assumes all 
risks (including the risk of suit) that the product or any use of the product will 
infringe existing or subsequently issued patents, trademarks, or copyrights. 

a)  Any documentation included with Product purchased from ProSoft is 

protected by copyright and may not be duplicated or reproduced in any 
form without prior written consent from ProSoft. 

b)  ProSoft’s technical specifications and documentation that are included 

with the Product are subject to editing and modification without notice. 

c)  Transfer of title shall not operate to convey to Customer any right to make, 

or have made, any Product supplied by ProSoft. 

d)  Customer is granted no right or license to use any software or other 

intellectual property in any manner or for any purpose not expressly 
permitted by any license agreement accompanying such software or other 
intellectual property. 

e)  Customer agrees that it shall not, and shall not authorize others to, copy 

software provided by ProSoft (except as expressly permitted in any 
license agreement accompanying such software); transfer software to a 
third party separately from the Product; modify, alter, translate, decode, 
decompile, disassemble, reverse-engineer or otherwise attempt to derive 
the source code of the software or create derivative works based on the 
software; export the software or underlying technology in contravention of 
applicable US and international export laws and regulations; or use the 
software other than as authorized in connection with use of Product. 

f) 

Additional Restrictions Relating To Software And Other Intellectual 
Property

 

In addition to compliance with the Terms of this Warranty, Customers 
purchasing software or other intellectual property shall comply with any 
license agreement accompanying such software or other intellectual 
property. Failure to do so may void this Warranty with respect to such 
software and/or other intellectual property. 

2.3.5 Disclaimer 

of 

all Other Warranties 

The Warranty set forth in What Is Covered By This Warranty (page 21) are in lieu 
of all other warranties, express or implied, including but not limited to the implied 
warranties of merchantability and fitness for a particular purpose. 

Summary of Contents for InRax PC56

Page 1: ...PC56 ControlLogix Platform In Rack Industrial PC November 18 2009 QUICK START GUIDE ...

Page 2: ...dules B Warning Explosion Hazard Do not disconnect equipment unless power has been switched off or the area is known to be non hazardous C These products are intended to be mounted in an IP54 enclosure The devices shall provide external means to prevent the rated voltage being exceeded by transient disturbances of more than 40 This device must be used only with ATEX certified backplanes D DO NOT O...

Page 3: ... write or call us ProSoft Technology 5201 Truxtun Ave 3rd Floor Bakersfield CA 93309 1 661 716 5100 1 661 716 5101 Fax www prosoft technology com support prosoft technology com Copyright ProSoft Technology Inc 2009 All Rights Reserved PC56 Quick Start Guide November 18 2009 ProSoft Technology ProLinx inRAx ProTalk and RadioLinx are Registered Trademarks of ProSoft Technology Inc All other brand or...

Page 4: ......

Page 5: ...roSoft Technology Product Documentation 3 1 Installing the PC56 Embedded PC 7 1 1 Carton Content 7 1 2 Verify Jumper Settings 9 1 3 Optional Module Connections 11 1 4 Installing Modules 11 1 5 Connecting Peripherals 12 1 6 Verify Operation 17 2 Support Service Warranty 19 2 1 How to Contact Us Technical Support 19 2 2 Return Material Authorization RMA Policies and Conditions 20 2 3 LIMITED WARRANT...

Page 6: ...PC56 ControlLogix Platform Contents In Rack Industrial PC Quick Start Guide Page 6 of 25 ProSoft Technology Inc November 18 2009 ...

Page 7: ...per Settings 9 Optional Module Connections 11 Installing Modules 11 Connecting Peripherals 12 Verify Operation 17 This Quick Start Guide will help you get your PC56 Embedded PC up and running If you need additional information refer to the appropriate user manual located on the PC56 CD ROM shipped with your module 1 1 Carton Content Your new PC56 Embedded PC is shipped with the following PC56 Embe...

Page 8: ...lLogix backplane The PC56 Embedded PC and each IDE or expansion module will each take a slot on the ControlLogix backplane For example if your purchased the PC56 XP IDE you will need two available slots on the backplane The slots must be side by side Additional modules take additional slots and all are required to be side by side To install the PC56 Embedded PC or any of the other modules 1 Check ...

Page 9: ...Industrial PC ProSoft Technology Inc Page 9 of 25 November 18 2009 1 2 Verify Jumper Settings Jumpers are preconfigured and in most cases should not be changed The following diagrams show the jumper configurations for the PC56 HIST module 1 2 1 RS 232 Default 1 2 2 RS 422 Jumper Setting ...

Page 10: ...Platform Installing the PC56 Embedded PC In Rack Industrial PC Quick Start Guide Page 10 of 25 ProSoft Technology Inc November 18 2009 1 2 3 RS 485 Jumper Setting 1 2 4 Jumper Configurations for IDE Drives IRQ 14 IRQ 15 ...

Page 11: ...de of the PC56 as shown in the diagram Be careful when inserting the connector as improper insertion may cause damage to the pins 1 4 Installing Modules Caution Although the PC56 is hot swappable it is NOT recommended that you insert the module into the rack while power to the rack is on Shut down power to the ControlLogix rack before performing this step Align the module s with the top and bottom...

Page 12: ...abel provides descriptions of the various ports and connectors Caution Make sure power to the ControlLogix rack is OFF before connecting peripherals to the PC56 1 5 1 Cable Connections The application ports on the PC56 module support RS 232 RS 422 and RS 485 interfaces Please inspect the module to ensure that the jumpers are set correctly to correspond with the type of interface you are using Note...

Page 13: ...th the module This port permits a PC based terminal emulation program to view configuration and status data in the module and to control the module The cable for communications on this port is shown in the following diagram RS 232 Application Port s When the RS 232 interface is selected the use of hardware handshaking control and monitoring of modem signal lines is user definable If no hardware ha...

Page 14: ...e of connection is required between the module and a modem or other communication device The Use CTS Line parameter for the port configuration should be set to Y for most modem applications RS 232 Null Modem Connection Hardware Handshaking This type of connection is used when the device connected to the module requires hardware handshaking control and monitoring of modem signal lines ...

Page 15: ... 25 November 18 2009 RS 232 Null Modem Connection No Hardware Handshaking This type of connection can be used to connect the module to a computer or field device communication port Note If the port is configured with the Use CTS Line set to Y then a jumper is required between the RTS and the CTS line on the module connection RS 422 ...

Page 16: ...uired for this interface is shown below Note Terminating resistors are generally not required on the RS 485 network unless you are experiencing communication problems that can be attributed to signal echoes or reflections In this case install a 120 ohm terminating resistor on the RS 485 line RS 485 and RS 422 Tip If communication in the RS 422 RS 485 mode does not work at first despite all attempt...

Page 17: ...17 of 25 November 18 2009 1 6 Verify Operation Connect your peripherals such as monitor keyboard and mouse to the PC56 using the appropriate connectors Turn on power to the ControlLogix rack If your PC56 system is equipped with a Windows operating system the appropriate Windows desktop will appear on your monitor after boot up ...

Page 18: ...PC56 ControlLogix Platform Installing the PC56 Embedded PC In Rack Industrial PC Quick Start Guide Page 18 of 25 ProSoft Technology Inc November 18 2009 ...

Page 19: ...ocessor and user data files as viewed through and LED patterns on the processor 3 Details about the serial devices interfaced if any 2 1 How to Contact Us Technical Support Internet Web Site www prosoft technology com support E mail address support prosoft technology com Asia Pacific 603 7724 2080 support asia prosoft technology com Languages spoken include Chinese English Europe location in Toulo...

Page 20: ... must be shipped freight prepaid in the original shipping container or equivalent to the location specified by ProSoft and be accompanied by proof of purchase and receipt date The RMA number is to be prominently marked on the outside of the shipping box Customer agrees to insure the Product or assume the risk of loss or damage in transit Products shipped to ProSoft using a shipment method other th...

Page 21: ... Limited Warranty All sales of software or other intellectual property are in addition subject to any license agreement accompanying such software or other intellectual property 2 3 1 What Is Covered By This Warranty a Warranty On New Products ProSoft warrants to the original purchaser that the Product that is the subject of the sale will 1 conform to and perform in accordance with published speci...

Page 22: ...any IEC 61131 3 C or any variant of C programming languages not furnished by ProSoft v use of the Product for purposes other than those for which it was designed vi any other abuse misapplication neglect or misuse by the Customer vii accident improper testing or causes external to the Product such as but not limited to exposure to extremes of temperature or humidity power failure or power surges o...

Page 23: ...d modification without notice c Transfer of title shall not operate to convey to Customer any right to make or have made any Product supplied by ProSoft d Customer is granted no right or license to use any software or other intellectual property in any manner or for any purpose not expressly permitted by any license agreement accompanying such software or other intellectual property e Customer agr...

Page 24: ... is understood to be the complete and exclusive agreement between the parties suspending all oral or written prior agreements and all other communications between the parties relating to the subject matter of this Warranty including statements made by salesperson No employee of ProSoft or any other party is authorized to make any warranty in addition to those made in this Warranty The Customer is ...

Page 25: ...WARRANTY 21 N No Other Warranties 24 O Optional Module Connections 11 P PC56 Modules 2 PC56 Battery Warning 3 Pinouts 12 16 Procedures for Return of Units Out of Warranty 20 Procedures for Return of Units Under Warranty 20 ProSoft Technology Product Documentation 3 R Return Material Authorization RMA Policies and Conditions 20 RS 232 Modem Connection 14 Null Modem Connection Hardware Handshaking 1...

Reviews: