![ProSoft Technology inRAx 3170-PDP User Manual Download Page 113](http://html1.mh-extra.com/html/prosoft-technology/inrax-3170-pdp/inrax-3170-pdp_user-manual_1618906113.webp)
Reference 3170-PDP
♦
FLEX Platform
FLEX I/O™ PROFIBUS Adapter
ProSoft Technology, Inc.
Page 113 of 152
August 23, 2007
Module = "Flex I/O empty slot/Full format" 0x00, 0x00
Ext_Module_Prm_Data_Len = 3
Ext_User_Prm_Data_Const(0) = 0xFF, 0xFF, 0x00
EndModule
; AC Modules
;--------------
; Flex I/O module 1794-IA8, (default config= 1 word in, 0 word out)
Module = "1794-IA8 / Full format" 0x50, 0x00
Ext_Module_Prm_Data_Len = 5
Ext_User_Prm_Data_Const(0) = 0x02, 0x85, 0x10, 0x00, 0x00
;Config word 1
Ext_User_Prm_Data_Ref(4) = 4
EndModule
; Flex I/O module 1794-IA8I, (default config= 1 word in, 0 word out)
Module = "1794-IA8I / Full format" 0x50, 0x00
Ext_Module_Prm_Data_Len = 5
Ext_User_Prm_Data_Const(0) = 0x02, 0x80, 0x10, 0x00, 0x00
;Config word 1
Ext_User_Prm_Data_Ref(4) = 38
EndModule
; Flex I/O module 1794-IA16, (default config= 2 word in, 0 word out)
Module = "1794-IA16 / Full format" 0x51, 0x00
Ext_Module_Prm_Data_Len = 5
Ext_User_Prm_Data_Const(0) = 0x02, 0x09, 0x10, 0x00, 0x00
;Config word 0
Ext_User_Prm_Data_Ref(4) = 39
Ext_User_Prm_Data_Ref(4) = 40
EndModule
; Flex I/O module 1794-OA8, (default config= 0 word in, 1 word out)
Module = "1794-OA8 / Full format" 0x00, 0x60
Ext_Module_Prm_Data_Len = 5
Ext_User_Prm_Data_Const(0) = 0x01, 0x95, 0x01, 0x00, 0x00
;Safe state word 1
Ext_User_Prm_Data_Ref(4) = 16
EndModule
; Flex I/O module 1794-OA8I, (default config= 0 word in, 1 word out)
Module = "1794-OA8I / Full format" 0x00, 0x60
Ext_Module_Prm_Data_Len = 5
Ext_User_Prm_Data_Const(0) = 0x01, 0x9C, 0x01, 0x00, 0x00
;Safe state word 1
Ext_User_Prm_Data_Ref(4) = 16
EndModule
; Flex I/O module 1794-OA16, (default config= 1 word in, 1 word out)
Module = "1794-OA16 / Full format" 0x50, 0x60
Ext_Module_Prm_Data_Len = 5
Ext_User_Prm_Data_Const(0) = 0x01, 0x0D, 0x01, 0x00, 0x00