IMC-BHx-AC
Industrial Media Converter
Ethernet over Belden 9463 “Blue Hose”
July 24, 2014
INSTALLATION GUIDE
Page 1: ...IMC BHx AC Industrial Media Converter Ethernet over Belden 9463 Blue Hose July 24 2014 INSTALLATION GUIDE...
Page 2: ......
Page 3: ...661 716 5100 1 661 716 5101 Fax www prosoft technology com support prosoft technology com Copyright 2014 ProSoft Technology Inc All rights reserved IMC BHx AC Installation Guide July 24 2014 ProSoft T...
Page 4: ...IMC BHx AC Installation Guide Page 4 of 30 ProSoft Technology Inc July 24 2014...
Page 5: ...Cabling 12 3 4 Cabling Location Examples 12 3 5 Using a Repeater 17 3 5 1 Using Repeaters on the Network 17 4 LED Functionality 19 4 1 Remote I O Serial Status LEDs 19 5 Reference 21 5 1 Device Speci...
Page 6: ......
Page 7: ...red to the baud rate of the remote I O data Three Ethernet ports are also available on the Master and Slave modules allowing up to three Ethernet devices to be connected to the media converter before...
Page 8: ...ble via switch 1 RIO Trunk port 1 RIO Drop port Note The Trunk line requires a 150 Ohm resistor at each end Each drop line also requires a 150 Ohm resistor 1 2 Slave Each network requires at least one...
Page 9: ...end of this guide 2 1 Package Content The following tables show the components including with IMC BHx AC modules Ensure that all items are present before starting the installation IMC BHM AC Master Q...
Page 10: ...ctors 357 0148 CONN 4 Pos Term Block Pluggable GRN Screw Flange 173 00009 IMC BHR AC Repeater Qty Part Name Part Number Description 1 IMC BHR AC Module IMC BHR AC Ethernet over Blue Hose Industrial Me...
Page 11: ...low all safety instructions when installing this or any other electronic devices Failure to follow safety procedures could result in damage to hardware or data or even serious of death to personnel Re...
Page 12: ...that may damage the Remote I O device Trunk Drop Termination Each trunk segment as well as each Drop Line of Blue Hose cabling should be terminated with 2 150 Ohm Resistors one on each end of the phys...
Page 13: ...Installation ProSoft Technology Inc Page 13 of 30 July 24 2014 Do NOT attempt to connect a remote I O network device to a Master or Slave Trunk connector...
Page 14: ...Installation Page 14 of 30 ProSoft Technology Inc July 24 2014 The following diagram shows the cabling configuration between a PLC 5 and RIO devices...
Page 15: ...stallation ProSoft Technology Inc Page 15 of 30 July 24 2014 The device also provides three RJ 45 Ethernet connectors located on the front of the unit These are used for the CLX EtherNet IP controller...
Page 16: ...Installation Page 16 of 30 ProSoft Technology Inc July 24 2014 Multipoint Example This example shows three Slaves connected to a single Master...
Page 17: ...the Specification and Performance Charts 3 5 1 Using Repeaters on the Network Repeaters should be used in a system when any of the following conditions exist More than six slaves are being used More t...
Page 18: ...Installation Page 18 of 30 ProSoft Technology Inc July 24 2014...
Page 19: ...tus Description Green Remote I O Good RIO Traffic Active Remote I O Signal Detected Immediate LED response from Yellow to Green Integration of RIO serial data wave for is acceptable Yellow Remote I O...
Page 20: ...Page 20 of 30 ProSoft Technology Inc July 24 2014 FRONT BOTTOM POWER 120 240 VOLTS AC 50 60HZ G N L1 PORT 1 PORT 2 PORT 3 ETHERNET Trunk Drop 1 SH 2 TRUNK 1 SH 2 DROP TRUNK LED TRUNK CONNECTOR DROP L...
Page 21: ...bling Type Trunk Drop Belden 9463 Blue Hose Ethernet Bandwidth 1 4 Mbps 20 40 Mbps Peak Remote I O Baud Rates 57 6K and 115 2K Din Rail Mountable Yes IMC BHS AC Slave Dimensions 8 3 x 2 7 x 4 3 in 2 1...
Page 22: ...Bandwidth 1 4 Mbps 20 40 Mbps Peak Remote I O Baud Rates 57 6K and 115 2K Din Rail Mountable Yes 5 2 Maximum System Specifications Single Trunk Segment Systems Without Repeaters Number of RIO devices...
Page 23: ...Reference ProSoft Technology Inc Page 23 of 30 July 24 2014 5 3 Typical Performance Characteristics 5 3 1 Single Bus Segment System Without Repeaters IP Only Up to 8 Slaves per Bus Segment...
Page 24: ...Reference Page 24 of 30 ProSoft Technology Inc July 24 2014 IP with 57 6K Baud Remote I O Up to 8 Slaves per Bus Segment IP with 115 2K Baud Remote Up to 8 Slaves per Bus Segment...
Page 25: ...Reference ProSoft Technology Inc Page 25 of 30 July 24 2014 5 3 2 Multiple Bus Segment System 1 4 Repeaters IP Only Up to 6 Slaves per Bus Segment...
Page 26: ...Reference Page 26 of 30 ProSoft Technology Inc July 24 2014 IP with 57 6K Baud Remote I O Up to 6 Slaves per Bus Segment IP with 115 2K Baud rate Remote I O Up to 6 Slaves per Bus Segment...
Page 27: ...Reference ProSoft Technology Inc Page 27 of 30 July 24 2014 5 3 3 Multiple Bus Segment System 5 8 Repeaters IP Only Up to 6 Slaves per Bus Segment...
Page 28: ...Reference Page 28 of 30 ProSoft Technology Inc July 24 2014 IP with 57 6K Baud Remote I O Up to 6 Slaves per Bus Segment IP with 115 2K Baud Remote I O Up to 6 Slaves per Bus Segment...
Page 29: ...sue is hardware related we will also need information regarding Module configuration and associated ladder files if any Module operation and any unusual behavior Configuration Debug status information...
Page 30: ...ges spoken include English Hindi North America location in California Tel 1 661 716 5100 E mail support prosoft technology com Languages spoken include English Spanish Latin America Oficina Regional T...