not be over 10 seconds. The current measurement shall be carried out 1
minute after the completion of previous measurement.
4.2.11 AC current
Measuring range
Resolution
Accuracy
60mA
0.01mA
±(1% R 3 digits)
600mA
0.1mA
10A
10mA
±(2% R 10 digits)
Overload protection:
Protective tube for mA measuring range (F500mA/250V) ; Protective
tube for 10A measuring range (F10A/250V) .
Maximal input voltage: mA position: 600mA DC/AC (valid value);
10A position: 10A DC/AC (valid value) When the
measured current is over 5A, the duration of continuous measurement shall
not be over 10 seconds. The current measurement shall be carried out 1
minute after the completion of previous measurement.
Frequency response: 40Hz-1kHz True RMS
4.2.12 Temperature (depends on different model, only for
the instruments with it)
Measuring range
Resolution
Accuracy
-20
℃
~1000
℃
1
℃
(1.0% r3digits)
-4
℉
~ 1832
℉
1
℉
(1.0% r3digits)
Overload protection: 600V DC/AC
5. Meter maintenance
This section provides the basic information on maintenance, including the
descriptions about replacement of protective tubes and batteries. Do not
attempt the meter maintenance unless you are experienced in maintenance
Summary of Contents for MT-1707