6
Overload Protection: 250V dc or rms. ac.
RESISTANCE
Maximum Open Circuit Voltage: 2.8V
Overload Protection: 250V dc or rms. ac for all ranges.
TRANSISTOR hFE TEST (0-1000)
BATTERY TESTING
Range
Resolution
Accuracy
±1% of rdg ± 5 digits
±1% of rdg ± 5 digits
±1% of rdg ± 5 digits
±1% of rdg ± 5 digits
±1.5% of rdg ± 5 digits
200
2k
20k
200k
2M
0.1
1
10
100
1k
Range
Test Range
Test Current
Test Voltage
NPN & PNP
0-1000
Ib=10µA
Vce=2.8V
±2.5% of rdg +2 digits
Range
Accuracy
1.5V
OPERATING INSTRUCTIONS DC VOLTAGE
MEASUREMENT
1. Connect the red test lead to the "V.Ω.mA" jack and the black lead
to the "COM" jack.
2. Set rotary switch at desired DCV position. If the voltage to be
measured is not known beforehand, set range switch at the
highest range position and then reduce it until satisfactory
resolution is obtained.
3. Connect test leads across the source or load being measured.
4. Read voltage value on the LCD display along with the polarity of
the red lead connection.