background image

OPERATING  PRINCIPLE 
OF THE  ELECTRO-GEN

™ 

FOGGER

The 

ELECTRO-GEN  UNIT

  is  a  dual  purpose  chemical  application  de-

vice:  A  THERMAL  FOGGER  which  produces  a  very  small  size  droplet 
particle and an optional electric sprayer which produces a cold mist spray 
similar  to  that  produced  by  an  aerosol  can.

ColD  sPRaYInG  MoDe

At the touch of the trigger, an electric pump draws solution from the solu-
tion  reservoir. The  solution  is  pressurized  and  forced  through  a  specially 
restricted  orifice  where  the  solution  is  atomized  into a cold mist.
In  the cold spraying mode the operator has a choice of utilizing water 
based or solvent based formulations, such as fabric protectors, deodor-
ants,  flame  retardants,  spotters,  insecticides,  etc.

Special  Advisory

The  use  of  resinous  materials  such  as  duct  sealants,  etc.  may  clog  and 
damage  the  unit  and  are  to  be  avoided.

THeRMal  foGGInG  MoDe

At  the  touch  of  the  trigger,  an  electric  pump  forces  solution  drawn  from  the 
solution reservoir through an atomizing nozzle and into a thermostatically 
controlled heating chamber in the barrel. The solution is vaporized instantly 
and  a  cloud  of  smokelike  fog  surges  out  of  the  end  of  the  barrel.

Application  Advisory

For odor removal applications 

always

 utilize ODORx® Thermo 55™. ODORx 

Thermo 55 is ready-to-use and should not be diluted with water. For pest 
control applications be sure insecticide label permits THERMAL FOGGING.

For best results 

dry fog 

is recommended. The dryer the fog the smaller 

the droplets, resulting in improved penetration and economical treatment.
Dryness of the fog is controlled by the rate of solution passing through 
the heating chamber. This flow rate is controlled by turning the adjustment 
knob  clockwise for a dryer fog, and counter clockwise for a damper fog.

Summary of Contents for ELECTRO-GEN

Page 1: ...ELECTRO GEN OPERATOR S MANUAL For safe operating and maintenance instructions read carefully Thermal Fogger Electric Sprayer...

Page 2: ...S MANUAL Copyright 2010 ProRestore Products Coraopolis PA 15108 Reproduction in any manner in whole or in part in English or in other languages is prohibited All Rights Reserved Printed for ProRestore...

Page 3: ...Cold Fogging Spraying 3 Thermal Fogging 4 Electrical Source 4 Pest Control Tips 4 Advantages of Thermal Fogging 5 Tips on Thermal Fogging Outdoors 5 Advantages of Spraying 5 Special Procedure for Heav...

Page 4: ...t sealants etc may clog and damage the unit and are to be avoided THERMAL FOGGING MODE At the touch of the trigger an electric pump forces solution drawn from the solution reservoir through an atomizi...

Page 5: ...uge length not to exceed 25 linear feet 7 6 meters WARNING Keep away from children and pets Fire and or explosion may occur if used in confined area Under certain conditions a flame may be produced at...

Page 6: ...efully Be careful to avoid damaging target surfaces when cold fogging wet spraying Prior to each use examine both electrical extension cord and unit s primary electrical cord for signs of damage or de...

Page 7: ...n adjustment knob clockwise to obtain a dry fog With the proper fog setting you shouldn t see moisture on an 8 x 12 20cm x 30cm minimum piece of paper or cardboard when passed through the fog about a...

Page 8: ...d utilize the available outdoor air currents to circulate and carry the fog over the target area whenever and wherever possible Advantages of Spraying 1 Preserves the potency of insecticides adversely...

Page 9: ...r 1 gallon 3 8 Liters ODORx Unsoot 1 1 quart 0 95 Liters ODORx 9 D 9 5 ounces 150ml ODORx Last Resort Fill the balance with water to make 5 gallons Apply with low pressure electric sprayer or commerci...

Page 10: ...teristics Thermo 55 Cherry The strongest of the ODORx Thermo 55 SERIES recommended for moderate to heavy smoke odor situations Provides long lasting re sidual air freshening characteristics Works syne...

Page 11: ...odor counteractants are compounded from the finest base materials and constituents available It is recom mended to flush the system without the barrel with mineral spirits to ensure optimal perfromanc...

Page 12: ...r clogged pump mechanisms or for periodic maintenance Note Unit s motor must make normal buzzing sound for this maintenance repair technique to be effective 1 Protect work area from solvent related da...

Page 13: ...al solution Remove nozzle from threaded stem clean nozzle by spraying with aerosol carburetor cleaner or blowing out with air WARNING DO NOT ATTEMPT TO UNCLOG NOZLE BY INSERTING SHARP OBJECT OR DAMAGE...

Page 14: ...102259002 1 Gasket 3 102259003 1 Pump Parts Kit 4 102259004 1 Nozzle Nut Sapphire Orifice Restricted Flow 5 102259005 1 Spinner Spring Assembly 6 102259006 1 Heat Barrel Assembly Complete 7 102259007...

Page 15: ...4660 Elizabeth Street Coraopolis PA 15108 Copyright 2010 ProRestore Products...

Reviews: