18 PRO290 USER MANUAL: Operating & Safety Instructions
NO LIGHTS COME ON AND STEAMER DOES NOT HEAT UP
Probable Cause
Solution
Steamer is not switched on, fuse
in plug has failed or power outlet
is not working/switched off.
Check steamer is switched on, plug into another
power outlet, if steamer still not working try changing
fuse in plug.
If steamer is still not working call your dealer to arrange service.
DIRTY WATER COMING OUT OF FILLER CAP
Probable Cause
Solution
Steamer needs cleaning out
or descaling.
Remove hose and poles from steamer and flush boiler
as directed in 6.2 Cleaning your Steamer. If steamer
has not been descaled recently, descale as directed
in 6.3 Descaling your Steamer.
Failure to regularly clean the boiler and descale regularly will result in damage to the element.
Your Propress steamer operates at high temperatures and produces steam
which can burn – use extreme caution. Troubleshooting should only be
carried out by a competent person. Always allow steamer to cool down
before commencing trouble shooting.
8. PROPRESS TROUBLESHOOTING