P E R C H   H E I G H T   A D J U S TA B L E   D E S K

6. 

CONNECT THE MOTOR CABLES TO THE CONTROL BOX.

 

The motor cable plug-connection has to click into place. 

Connections to the control box: M1-M2 = Connectors for the columns. D1 or D2 = Connectors for the handset.

7. 

CONNECT THE HANDSWITCH (HS) CABLE TO THE CONTROL BOX. The handswitch can be connected to either the D1 or D2 port of the 
control box.

8. 

CONNECT THE SUPPLIED POWER CORD (AC) TO THE CONTROL BOX.

9. 

ATTACH ALL CABLES TO THE TABLE FRAME OR ON THE UNDERSIDE OF THE WORK SURFACE. Attach cables in order to avoid any 

damage during operation. Never wrap cables and/or cords around the columns.

A S S E M B L Y   I N S T R U C T I O N S

proproffice.com          5

Summary of Contents for L42 W24 H26-46

Page 1: ...ture Furniture intended for placement on floor Do not place items over 300lb on furniture C L E A N I N G C A R E Clean surfaces with a dry or damp soft cloth Do not use abrasive oil or chemical based cleaners It is recommended to use coasters to protect surface from heat and water Do not leave spills unattended D I M E N S I O N S L42 W24 H26 46 L42 W30 H26 46 L48 W24 H26 46 L48 W30 H26 46 L60 W2...

Page 2: ... 6mm Hex Key 1 7 M10x1 5 30mm Screw 4 8 10 x Screw 24 9 Table Top 1 PARTS Qty Package 1 Column 2 2 Foot 2 3 Handswitch 1 4 Control Box 1 5 Power Cord 1 6 6mm Hex Key 1 7 M10x1 5 30mm Screw 4 8 10 x Screw 36 9 Anti Sag Bar 1 10 Table Top 1 7 2 1 8 3 6 5 4 9 1 8 9 2 7 6 3 5 4 10 F O R TA B L E S U P TO 60W F O R TA B L E S OV E R 60W proproffice com 2 ...

Page 3: ...width and style 2 FOR SELECT CONFIGURATIONS ASSEMBLE THE ANTI SAG BAR TO THE WORK SURFACE Use the 10 x screws to fasten the anti sag bar onto the table top Center the anti sag bar on the table top 152mm 6IN in from the back of the table A S S E M B LY I N S T R U C T I O N S 152mm 6IN BACK B A B A SPACING GUIDE DIMENSION 24IN T STYLE 30IN T STYLE 24IN C STYLE 30IN C STYLE A 38mm 1 5IN B 272mm 10 7...

Page 4: ...ch bolt should be tight ened once Do not re torque the first bolt after torquing the last 4 FASTEN THE CONTROL BOX AND HANDSWITCH TO THE WORK SURFACE Make sure the control box and handswitch are fastened in a location where all the cables will connect without being in tension Be sure to use approved screws per the table top supplier Repeat the same process for the other side 5 CONNECT THE COLLISIO...

Page 5: ...e handset 7 CONNECT THE HANDSWITCH HS CABLE TO THE CONTROL BOX The handswitch can be connected to either the D1 or D2 port of the control box 8 CONNECT THE SUPPLIED POWER CORD AC TO THE CONTROL BOX 9 ATTACH ALL CABLES TO THE TABLE FRAME OR ON THE UNDERSIDE OF THE WORK SURFACE Attach cables in order to avoid any damage during operation Never wrap cables and or cords around the columns A S S E M B L...

Page 6: ...ipping or collapsing make sure the desk frame is not overloaded by the weight of tabletop and objects on table Evenly distribute load excess loads near edges can reduce stability and lead to tip over Do not exceed maximum load including weight of desktop of 250 lb 113Kg Do not exceed edge load of 25 lb when positioning monitors or mounting accessories Do not sit or stand on table USE CARE WHEN MOV...

Page 7: ...ht of the table upwards maximum height If an attempt is made to set the container stop or shelf stop too close to the middle the controller signals this with 6 quiet click sounds Note This function is configuration dependent and is not available with every controller With the additional stops the safety of the table system can be increased in that the possible movement path is restricted SET UP SH...

Page 8: ...able OF DOUBLE CLICK SOUNDS WHEN STATUS INFORMATION 1 Supply of electrical power Normal Operation The system is functioning without any problems click sounds 1 Up key pressed Reset Initialization movement is required 1 Lower blockade detected Reset Table has reached the Reset position during the initialization movement The key can be released 1 Lower blockade detected Reset Initialization movement...

Page 9: ...e depending on version View Illustration B Maximum input current 5 A Maximum duty cycle 30 sec on 9 min off The drive system is tested according to the following standards UL 962 Issued 2019 05 21 Ed 4 Household and Commercial Furnishings CSA C22 2 68 Issued 2019 05 21 Ed 8 R2018 Motor Operated Appliances Household and Commercial Meets BIFMA x5 5 2021 ILLUSTRATION B Single Stage Dual Stage T E C H...

Reviews: