SECTION 11—BATTERIES
69
Disconnecting Battery Cables
WARNING
The use of rubber gloves is recommended when working with batteries.
NEVER allow any of your tools and/or battery cables to contact both battery termi-
nals at the same time. An electrical short may occur and serious personal injury or
damage may occur.
NOTE: For this procedure, refer to FIGURE 11.3.
1. Remove the seat. Refer to Removing/Installing the Seat Assembly on page 40.
2. Remove the batteries. Refer to Removing/Installing Batteries from/into Battery Tray
3. Cut the tie-wrap that secures the battery terminal cap in place (Detail “B” of
4. Slide terminal caps up onto the battery cables (FIGURE11.3).
5. Disconnect POSITIVE (+) battery cable from the POSITIVE (+) battery terminal
6. Disconnect NEGATIVE (-) battery cable from NEGATIVE (-) battery terminal
Charging Batteries
WARNING
NEVER attempt to recharge the batteries by attaching cables directly to the
battery terminals.
DO NOT attempt to recharge the batteries and operate the wheelchair at the same
time.
DO NOT attempt to recharge the batteries when the wheelchair has been exposed
to any type of moisture.
DO NOT attempt to recharge the batteries when the wheelchair is outside.
DO NOT sit in the wheelchair while recharging the batteries.
DO NOT attempt to recharge the batteries using both the on-board battery
charger and an independent battery charger (plugged into the joystick charger
port) at the same time. Doing so will reduce the life of the batteries.
Read and carefully follow the individual instructions for each charger (supplied or
purchased). If charging instructions are not supplied, consult a qualified technician
for proper procedures.