Required service actions
Open out drain valve (1) placed in lower part of tank (2).
The compressed air in the tank causes the removal of water to the
exterior.
After release valve stem should automatically close and stop airflow from tank.
In the event, that the valve stem resists returning to its setting, then
the whole drain valve must be unscrewed and cleaned, or replaced (if
it is damaged) - see section 5.3.5.
Draining water from air tank:
•
after each week of use.
5.3.5 CLEANING DRAIN VALVE
DANGER
Before dismantling drain valve release air from tank.
Required service actions
Reduce pressure in air tank.
Reduction of pressure in tank is achieved by tilting the drain valve
mandrel.
Unscrew valve.
Clean valve, purge with compressed air.
Change copper seal.
Screw in valve, fill air tank, and check tank tightness.
Cleaning valve:
•
every 12 months (before winter period).
Summary of Contents for T669
Page 2: ......
Page 6: ......
Page 11: ...SECTION 1 BASIC INFORMATION ...
Page 25: ...SECTION 2 SAFETY ADVICE ...
Page 41: ...SECTION 2 Pronar T669 2 17 FIG 2 3 Locations of information and warning decals ...
Page 42: ...Pronar T669 SECTION 2 2 18 ...
Page 43: ...SECTION 3 DESIGN AND OPERATION ...
Page 65: ...SECTION 4 CORRECT USE ...
Page 88: ...Pronar T669 SECTION 4 4 24 ...
Page 89: ...SECTION 5 MAINTENANCE ...
Page 117: ...SECTION 5 Pronar T669 5 29 FIG 5 11 Trailer s lubrication points part 1 ...
Page 118: ...Pronar T669 SECTION 5 5 30 FIG 5 12 Trailer s lubrication points part 2 ...
Page 132: ...Pronar T669 SECTION 5 5 44 ...
Page 133: ...NOTES ...
Page 134: ... ...