background image

Additional Instructions - 

Built In O3Elite Dual Ozone 

Generator - SSPO3-OZ

1. 

Attach the power cord to the 

ozone generator and plug it into a 

wall outlet.

2. 

Remove the dust caps. Plug tubing 

from your oxygen source into the 

Oxygen In port.

3. 

Attach the three way stopcock to 

the Ozone Out port. Attach a piece 

of silicone tubing to the horizontal 

arm of the stopcock and attach the 

other end of that tubing to the Ozone In port on 

the sauna. Make sure the check valve is closer to 

the Ozone In port as shown. 

Note: 

Until you are 

ready to turn on the ozone, or any time the sauna 

is heating  up or being used without ozone, make 

sure  the  Off  on  the  stopcock  is  pointed  to  the 

horizontal. When you’re ready to start directing 

ozone into the sauna, turn the Off to the vertical 

position.

4. 

Turn on your oxygen source. Turn the ozone 

generator dials to the settings desired. Use the 

gamma chart on the next page to determine the 

settings needed to obtain your desired level of 

ozone.

5. 

When  your  session  is  complete,  turn  off  the 

ozone generator. Let the oxygen run for a a 

couple of minutes and then turn off your oxygen.

Note about the Built In Ozone Model:

 This 

model can be used for ozone saunas or separately for other ozone applications. 

To use the ozone generator with other applications, connect silicone tubing to 

the vertical arm of the stopcock. Make sure Off is pointed toward the horizontal 

arm of the stopcock to divert ozone to that application.

Ozone Dials

Power

Oxygen In

Ozone Out

Ozone In

Horizontal

Vertical

Summary of Contents for SSP-OZ

Page 1: ...OPERATING MANUAL Steam Sauna Pro is a trademark or registered trademark of Promolife Inc 2017 Promolife Inc All Rights Reserved For Models SSP SSP OZ and SSPO3 OZ ...

Page 2: ...ning agents while cleaning CAUTION Do not operate your Steam Sauna Pro with the steam chamber lid open as steam is hot and can burn your skin Do not allow steam to directly contact your skin Do not use the door as a support to stand up or upon getting out of your Steam Sauna Pro Your Steam Sauna Pro is backed by a five 5 year limited warranty Please see last page for more information If you have qu...

Page 3: ...emoving the floor board and sponging up any standing water and wiping the inside surfaces with a towel and a dilute bleach solution or your favorite green cleaning product Inside your Steam Boiler Periodic cleaning of the steam boiler is recommended Using distilled water will reduce how often cleaning is needed Cleaning is recommended every three months with regular use To clean and sterilize your...

Page 4: ...tment is needed place the seat higher or lower 6 Plug your Steam Sauna Pro into a wall outlet Note The sauna requires a 15 amp or greater outlet 20 amp recommended 7 At this point you can put the seat pad and lumbar pillow into the sauna if you wish to use them 8 Turn your sauna on The On button is located on the left side of the digital control display 9 Set the temperature to 105 degrees Fahrenh...

Page 5: ...r several minutes Then turn off your oxygen Guide to Ozone Sauna Concentrations LOW DOSES getting started Oxygen 1 8 LPM Gamma Range 12 to 33 MEDIUM DOSE optimal range Oxygen 1 8 LPM Gamma Range 32 53 HIGH DOSE advanced higher intensity Oxygen 1 8 LPM Gamma Range 51 75 Tips To speed up the heat time of your Steam Sauna Pro place a towel over the neck opening To reduce steam escape and increase the...

Page 6: ...ointed to the horizontal When you re ready to start directing ozone into the sauna turn the Off to the vertical position 4 Turn on your oxygen source Turn the ozone generator dials to the settings desired Use the gamma chart on the next page to determine the settings needed to obtain your desired level of ozone 5 When your session is complete turn off the ozone generator Let the oxygen run for a a...

Page 7: ...ample To produce 26 gamma you can use 1 4 LPM of oxygen and turn dial 1 to 5 To produce 70 gamma you could use 1 8 LPM of oxygen and turn dial 1 to 5 and dial 2 to 4 Note Gamma ug ml O2 LPM 1 2 3 4 5 5 1 5 2 5 3 5 4 5 5 1 1 3 5 7 8 11 13 15 17 18 3 4 2 4 7 9 10 14 16 18 20 21 1 2 4 8 11 13 15 19 22 26 30 33 1 4 7 13 18 23 26 32 37 42 47 53 1 8 12 24 33 40 45 51 60 68 70 75 1 16 21 40 49 55 59 73 8...

Page 8: ...rom accidents negligence and or alteration of original equipment will cause this warranty to be null and void Warranty Claim Procedure The consumer is responsible for all transportation shipping costs on any claims under this warranty Claims must be in writing Do not return any equipment without first obtaining written authorization from Promolife Any equipment shipped to us without authorization w...

Reviews: