3
Assembly
WARNING!
Danger of toppling over
The centre of gravity of the single pump with standing
motor is relatively high.
– Only remove the pump from the crane hook once it
is firmly connected to the base.
–
Compare the dimensions on the dimension sheet
with those of the pump.
1.
Select a suitable motor - make sure that it corresponds to the
data from the "Motor data" table.
WARNING!
This is EX-relevant in areas at risk from explo‐
sion!
2.
Fit the motor correctly on the flange (qualified personnel).
Observe the coupling operating instructions!
WARNING!
This is EX-relevant in areas at risk from explo‐
sion!
With a claw coupling: Make sure that the claw on the motor
shaft is fixed at the correct height – see Fig. Fig. 1.
3.
ATEX pumps only: Ensure that there is also potential equali‐
sation between the motor and drive unit.
4.
As you have converted an "incomplete machine" into a com‐
plete machine, you must:
n
Perform an assessment of conformity
n
Perform a risk assessment
n
Produce an EC Declaration of Conformity
n
Fit your own nameplate
n
With ATEX pumps: additionally perform an ignition
hazard assessment.
n
Complete the pump documentation / operating instruc‐
tions.
n
...
Motor installation - with designs
without a motor
Assembly
10