Identity code

The identity code describes the external modules

for the DULCOMARIN

®

.

DXMa External modules for the DULCOMARIN

®

 

 

Module:

M

M module, measuring module: pH, ORP, temperature

A

A module, control module: 3 pumps and 4 analogue outputs

R

R module, control module: Chlorine gas metering device with feedback 

1) 2)

N

N module, power supply module without relay 

1) 2)

P

P module, power supply module without relay, only mounting type 

‘0’  

2)

I

I module, current input module, 3 mA inputs, 2 digital inputs

 

 

Mounting type:

0

Without housing, only P-module (IP 00)

W

Wall mounted (IP 65)

H

Mounting rail (IP 20)

E

Upgrade module (insert module for DXCa, IP 20)

 

 

Design:

0

With controls

2

Without controls

3

Without controls (only mounting type 

‘E’ )

 

 

Application:

0

Standard

S

Swimming pool (only M module)

 

 

Language:

00

No controls 

2)

EN

German

EN

English

ES

Spanish

FR

French

IT

Italian

 

 

Certification:

00

No certification, only P module without housing

01

CE certification

1)

 only mounting type W wall mounting / 

2)

 only in version 

‘2’  without operation

Identity code

 

 

 

3

Summary of Contents for DULCOMARIN DXMaR Series

Page 1: ...valid in conjunction with the Operating instructions for the DULCOMARIN EN 986539 Version BA DC 090 03 19 EN Please carefully read these operating instructions before use Do not discard The operator s...

Page 2: ...Table of contents 1 Identity code 3 2 Safety and responsibility 4 3 Handling the device 5 4 Wiring diagram 6 Table of contents 2...

Page 3: ...mounting type 0 2 I I module current input module 3 mA inputs 2 digital inputs Mounting type 0 Without housing only P module IP 00 W Wall mounted IP 65 H Mounting rail IP 20 E Upgrade module insert mo...

Page 4: ...rved without exception NOTICE Intended use You many only use the DXMaR R module to control a servomotor You many only use the DXMaR R module as part of a DULCOMARIN Any other uses or modifications are...

Page 5: ...60068 2 30 WARNING Danger of malfunctions Only trained personnel may install the DXMaR R module Only then can it be ensured that all com ponents of the control circuit are matched to each other and o...

Page 6: ...ering device in the event of a failure of the chlorine gas metering device doing the same with the power supply to the booster pump and the cir culating pump to shut the booster pump and the circulati...

Page 7: ...1 P2 n Type of contact Changeover contact with interference sup pressed varistors n Load capacity 250 V AC 3 A max 700 VA n Contact lifespan 20 x 105 switching operations Position feedback input XR n...

Page 8: ...986539 2 en_GB 2019 ProMinent GmbH Im Schuhmachergewann 5 11 69123 Heidelberg Telephone 49 6221 842 0 Fax 49 6221 842 419 Email info prominent com Internet www prominent com...

Reviews: