4.3.6 Commissioning
n
User qualification, commissioning: trained user, see
1.2 ‘Users' qualifications’ on page 5
4.3.6.1 Testing prior to commissioning the pump
The following tests are to be carried out:
n
Ensure that the pump has not been damaged during transpor‐
tation or storage. Immediately report any damage to the sup‐
plier
n
Check that the mains voltage is suitable for the motor
n
Ensure that the hose is suitable for the fluid to be conveyed
and that it is not damaged
n
Make sure that the temperature of the liquid does not exceed
the recommended temperature range
n
Only switch the pump on if it the front cover has been properly
attached
n
Check that the shoes are correctly fitted and fastened
n
Check that the hose and shoes are sufficiently lubricated
n
Check that the thermal overload protection (not included in the
delivery scope) corresponds to the value specified on the
motor type plate
n
Check whether the direction of rotation is correctly adjusted
n
Check that the optional electrical components are connected
and are working properly
n
Install a manometer in the pressure line if the back-pressure
value is unknown