11
Preventative maintenance
11.1 Stopping Production
Stop production before commencing maintenance work. Switch to
the
[MANUAL OPERATION] menu where different components
can be manually switched ON and OFF.
I.
II.
III.
A2013
1.
1.
1.
Fig. 36: Close the water tap (1)
I. Chlorinsitu-III 100 ... 500 g/h
II. Chlorinsitu-III 600 ... 1750 g/h
III. Chlorinsitu-III 2000 ... 3500 g/h
1.
Switch production to
[OFF].
2.
Perform a manual anode refresh five times.
ð
The system is now virtually product-free.
3.
Switch the booster pump to
[OFF].
4.
Switch the fan to
[OFF].
5.
Switch the main switch to
[OFF].
It is mandatory that the main switch is off during maintenance
work
6.
Close the water tap.