PROBLEM                        

SUGGESTED REMEDY

TROUBLESHOOTING

If you have difficulty operating your new ceiling fan, it may be the result of incorrect assembly, installation or 

wiring. In some cases, these installation errors may be mistaken for defects. If you experience any faults, please 

check the Troubleshooting section below. If a problem cannot be remedied or you are experiencing difficulty in 

installation, please contact the Service Department: 1-877-706-3267, 8 a.m. - 5 p.m. Central, Monday - Friday.

5. Remote control does 

not work:

W

ARNING: 

To reduce the risk of fire, electrical shock or personal injury,

 

shut off the power supply to fan before 

you begin any maintenance tasks.

1. Fan does not start:

2. Fan is noisy:

3. Fan wobbles:

4. Light does not work:

1. Make sure that the wall switch is turned ON.

2. Check main and branch circuit fuses or circuit breakers.

3. Check all wire connections from household supply wires to the fan. 

4. Make sure forward/reverse switch pushed completely left or right. Fan will not operate 

when switch is in the middle.

1. Make sure all screws in motor assembly are snug, but not overtightened.

2. Make sure the screws that attach the blade to the motor are tight.

3. Make sure wire connectors are not rattling against each other or against the interior wall 

of the light kit.

4. Some fan motors are sensitive to signals from Solid State variable speed controls. DO NOT 

USE a Solid State variable speed control.

5. Ensure fan does not wobble excessively (see Fan wobbles solutions below).

1. Ensure the mounting bracket is tightened securely to outlet box and outlet box is 

mounted firmly to ceiling joist.

2. Switch one blade with a blade from the opposite side. Or balance the fan using the blade 

balancing kit.

3. If blade wobble is still noticeable, interchanging two adjacent (side by side) blades can 

redistribute the weight and possibly result in smoother operation.

1. Check for loose or disconnected 9-pin and/or single-pin connectors in switch housing or 

light kit.

2. Check for faulty light bulbs.

3. Ensure total wattage of bulbs does not exceed 180 watts (for incandescent bulbs only).

1.  After installation is complete, switch the power off and back on again. Within 30 seconds, 

press and hold the “LEARN” button, located in the battery compartment, for 5 seconds. 

Fan will turn on at low speed and light off. This confirms that the SMART SYNC is active.

2.  Insert new 12V battery in battery compartment of the remote control.

3.  If there are several fans in proximity, turn power off to other fans and re-sync the remote 

(see Corrective Action 1 above).

Summary of Contents for Eclora 51672

Page 1: ......

Page 2: ...Washer KK Support Washer MM Secondary Spring Washer Unpack your fan and check the contents You should have the following items PACKAGE CONTENTS HARDWARE CONTENTS Note Some extra hardware has been inc...

Page 3: ...selecting a location for installation ensure the blades will be at least 30 inches from any wall or obstruction and at least 7 feet above the floor DIMENSION REFERENCE LOCATION FOR INSTALLATION C A B...

Page 4: ...CAN ICES 005 B NMB 005 B This device complies with part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 this device mus...

Page 5: ...wall To reduce the risk of fire electric shock or personal injury mount to outlet box marked acceptable for fan support and use mounting screws provided with the outlet box The installation has to be...

Page 6: ...ely remove two mounting bracket screws from opposite sides of the mounting bracket 3 Feed the supply wires from the outlet box through the center hole in the mounting bracket Then secure the mounting...

Page 7: ...Hanging System If desired the braided cable can be cut and removed using wire cutters sold separately Skip to Step 8 For installation in Canada In compliance with building codes in Canada installation...

Page 8: ...ew Blade Screw Blade Slot Mounting Bracket Screw 9 Slide the top of the motor assembly over the mounting bracket aligning the slotted holes in the top of the motor assembly with the pre loosened mount...

Page 9: ...cal power at the main fuse or circuit breaker and the wall switch Installation is complete Battery Cover Battery Compartment Front Back High Speed 14 Remove the battery cover from the back of the remo...

Page 10: ...light off and on Press and hold light control button to dim or brighten the lights Reverse Switch In warmer weather push the reverse switch left toward sun icon which will result in downward airflow c...

Page 11: ...ake sure wire connectors are not rattling against each other or against the interior wall of the light kit 4 Some fan motors are sensitive to signals from Solid State variable speed controls DO NOT US...

Page 12: ...ion is not covered by this warranty HKC assumes no responsibility whatsoever for fan installation Any service performed by a non licensed electrician will render the warranty invalid HKC s sole respon...

Reviews: