1 GENERAL INFORMATION 

 

1.1 Description 

 

The 

RP-080

 is a handy, versatile and easy to use signal 

generator with which satellite receivers and coaxial cables of 
buildings can be checked. 

 
 

1.2 Specifications 

 

 

RECEIVER TEST MODE

 

 

Frequency

 

 Pilot 

carriers 

 

UHF Band

 

85 MHz and 750 MHz  

 

L Band (IF Sat) 

1000 MHz and 2150 MHz 

 

Accuracy

 

±

 100 kHz 

Level

 

 

75 to 100 dB

µ

V (selectable in 1 dB 

steps) 

Accuracy 

 UHF 

Band 

±

 2 dB

 

 

  L (FI Sat) Band

 

±

 3 dB 

LEDs

 

Carrier output level (individually) 

Voltage and 22 kHz  
Indication 

13 V yellow LED illuminated 

 

 

13 V + 22 kHz yellow LED flashes 

 

 

18 V blue LED illuminated 

 

 

18 V + 22 kHz blue LED flashes 

 

Summary of Contents for RP-080

Page 1: ...USER S MANUAL SATELLITE RECEIVER CABLE TESTER RP 080 0 MI1483 Test Equipment Depot 800 517 8431 99 Washington Street Melrose MA 02176 TestEquipmentDepot com...

Page 2: ...mainly SAFETY RULES paragraph The symbol on the equipment means SEE USER S MANUAL In this manual may also appear as a Caution or Warning symbol Warning and Caution statements may appear in this manual...

Page 3: ...TY RULES 3 2 1 Descriptive Examples of Over Voltage Categories 5 3 OPERATING INSTRUCTION 7 3 1 Description of the controls and elements 7 3 2 Operating Instructions 9 3 2 1 Using combined with a TV le...

Page 4: ...11 06 RP 080...

Page 5: ...an be checked 1 2 Specifications RECEIVER TEST MODE Frequency Pilot carriers UHF Band 85 MHz and 750 MHz L Band IF Sat 1000 MHz and 2150 MHz Accuracy 100 kHz Level 75 to 100 dB V selectable in 1 dB st...

Page 6: ...ltitude up to 2000 m Temperature range from 5 C to 40 C Maximum relative humidity 80 up to 31 C decreasing lineally up to 50 at 40 C Mechanical features Dimensions 77mmWx85mmHx28mmD Weight 150 g INCLU...

Page 7: ...t Only indoor use When using some of the following accessories use only the specified ones to ensure safety Power adapter Use this instrument under the specified environmental conditions Remenber that...

Page 8: ...IRECT CURRENT ALTERNATING CURRENT DIRECT AND ALTERNATING GROUND TERMINAL PROTECTIVE CONDUCTOR FRAME TERMINAL EQUIPOTENTIALITY ON Supply OFF Supply DOUBLE INSULATION CLASS II protection CAUTION Risk of...

Page 9: ...080 2 1 Descriptive Examples of Over Voltage Categories Cat I Low voltage installations isolated from the mains Cat II Portable domestic installations Cat III Fixed domestic installations Cat IV Indus...

Page 10: ...11 06 6 RP 080...

Page 11: ...nt view 1 IF OUTPUT Output connector Frequency pilots output This jack will be connected with the IF input jack antenna input of the signal receiver 2 PILOT LEVEL INDICATORS LED indicators in red colo...

Page 12: ...89 dB v Figure 2 Output level Indication in dB V 4 OFF ON LOCK Power on off switch Output levels locking OFF Instrument power off deactivates the output levels ON Activates the output levels LOCK Loc...

Page 13: ...nal power supply Connector to power the instrument through an external DC source 13 18 V 120 mA 8 DC INPUT DC power supply adapter jack Jack to connect external DC power supply 12 18 V 120 mA 3 2 Oper...

Page 14: ...n section that is desired to check from the general panel or from one of the jack outlets of the TV signal distribution network 2 Connect the RP 080 OUTPUT 1 connector to one of the ends from section...

Page 15: ...at the two steps previously described in order to verify the following frequency band Consequently the correct equalisation of the selected installation section will be able to be verified IMPORTANT R...

Page 16: ...leaning recommendations CAUTION Do not use scented hydrocarbons or chlorides solvents Such products may attack the materials used in the construction of the cover The cover should be cleaned by means...

Page 17: ......

Reviews: