P1.A Series Exploded View 

P1.A Bottom 

Gear Housing 

(P1-120VN4 unit is shown)

(Rotated for clarity)

Position indicator 

viewport

Easily distinguishable 

yellow/red position 

indicator

Heavy Duty 

Drive Motor

Easily accessible 

switch & cam stacks

5mm Hex Key Override

Switch Card

Proportional Control Card

Spacer

Anti-Condensation 

Heater

Aluminum Casting

NEMA 4X Protection

NEMA 4X Cover Seals

Switch Logic Map and 

Switch/Cam Arrangement

Switch sequencing data is provided in the table 

below to show the change-of-state points during 

the rotation of the actuator from CCW to CW 

and back again. The red bar shows when that 

terminal makes with its respective common.
Switches 1 and 2 are set at the factory 

and should NOT be changed. The 

INCLUDED auxiliary switches SW3 & 

SW4 are for terminals 7 thru 12 and those 

set points may be modified if need be. 

FM14_P1A

 L

V VN4 V

er J 101614

Page 10 of 14 P1.A LV AdVanced Proportional Series

Mechanical Data

SW3 CCW AUX

(Factory Set - Adj)

SW4 CW AUX

(Factory Set - Adj)

F

E

C

B

A

-5

o

0

o

CW

CCW

85

o

5

o

90

o

95

o

}
}

Common Switch Terminal

Open

Not Closed

Closed

Not Open

}

Used by 

Controller

Summary of Contents for P1.A Series

Page 1: ...Installation Operation Manual This IOM is for the following ProMation Engineering Products P1 A 12VN4 AC P1 A 12VN4 DC P1 A 24VN4 AC P1 A 24VN4 DC...

Page 2: ...This page intentionally left blank...

Page 3: ...ts 2 Product Specifications 3 Shipping and Handling 3 Product Mounting and Setup 3 Installation Notes 4 Wiring Diagram 5 Layout of Controller 6 Check End of Travel Settings 6 Check End of Travel Setti...

Page 4: ...e Duty Cycle is directly related to heat excessively repositioning an actuator typically results in motor overheating which can cause permanent damage and or reduced service life Duty cycle can be cal...

Page 5: ...y CCW positions BEFORE applying power to the unit Warning DO NOT operate manual override when power is present Geartrain damage and personal injury may occur Do not use powered tools to turn the manua...

Page 6: ...d do not exceed the indicated length of the wire run for each model Proportional Control MAX distance between Actuator and Supply feet Actuator Voltage P1 A 12VAC DC P1 A 24VAC DC 1 5A 0 9A 18 55 184...

Page 7: ...D Running CCW Indicator Green LED Proportional Control DIP Switch Setting Default Functions DIP 1 Off Run Mode DIP 1 On Calibration CAL Mode DIP 2 Off Direct Acting Mode DIP 2 On Reverse Acting Mode D...

Page 8: ...d of Travel cams have set the rotation for 90 travel Reset to 90 travel and AutoCalibrate Power On DIP 5 on No Motor Movement Red or Green Motor Direction LEDs Flash Low Power Incoming Power too low T...

Page 9: ...tate the hex key to the LEFT 10 15 degrees to reset the switch roller arm Then snug the set screw up against the camshaft CW until slight pressure is felt Then SLOWLY rotate the hex key to the RIGHT u...

Page 10: ...the CW auxiliary switch adjustment Drive the actuator to its CW position Then use a 2 5mm hex key to free up the cam set screw Once it is free rotate the hex key to the LEFT 10 15 degrees to reset th...

Page 11: ...Pushed square dimension to three decimal places KHL REV A B C D E F Drive Coupling Fabrication Data 17 00 13 00 mm 0 669 0 005 0 000 in 17 00 13 00 mm 0 669 0 005 0 000 in 17 00 mm 0 669 in 127 mm 5 0...

Page 12: ...is provided in the table belowtoshowthechange of statepointsduring the rotation of the actuator from CCW to CW and back again The red bar shows when that terminal makes with its respective common Swi...

Page 13: ...ator I The actuator OUTPUT shaft will drive to the full CCW position while the INDICATOR cam shaft rotates to the full CW position as viewed from ABOVE the actuator II If this is NOT the correct stop...

Page 14: ...ves actuator to fully CW 7 The CW End of Travel switch opens and motor stops 8 The Green LED goes on and motor drives to fully CCW 9 The CCW End of Travel switch opens and motor stops 10 Red LED goes...

Page 15: ...otor drives to Fully CCW 4 The CCW End of Travel switch opens and motor stops 5 Red LED goes on and actuator drives to Fully CLOSED 6 The controller performs an internal Calibration of the Feedback Bl...

Page 16: ...n Pass Feedback Calibration Fail 20Hz Blink 30 seconds 1Hz Blink Inde nitely 20Hz Blink 3 seconds NO YES Did the Blue LED flash at 20Hz for three 3 seconds DIAG DIAG DIAG Check that Wire Jumper connec...

Page 17: ...ProMation Engineering Inc 16138 Flight Path Drive Brooksville FL 34604 Phone 352 544 8436 Fax 352 544 8439 www promationei com...

Page 18: ...igital form We regularly host customized educational webinars for our customers RapidQuote Most quotes and estimates are generated within hours of the request ProMation Engineering Services ProMation...

Reviews: