7.1.a Changing engine oil (PM13000D ES)

Place a container under the drain plug to

catch the oil. Use a wrench to open the

drain plug, then let the oil drain into a

container. If there is any sediment or carbon

on the inner rim or bottom of the tank, you

may use diesel to wipe it clean. Screw back

the drain plug.

Open the lock over the front cover, screw

the oil cap off as shown in the photo, pour

the oil until reaching the limit of the oil

gauge. Finally, screw back the cylinder head

stud.

7.1.b Changing engine oil (PM13000D ES

Silent)

Open the left door, use a wrench to release

the drain plug (don't take out the screw), put

the oil guide groove under the drain plug,

make it align with the plug and a container

then completely remove the drain plug. Let

the oil drain out. If there is any sediment or

debris on the inside of the receptacle use

diesel to wipe it clean.

Open the lid on the top of generator,

unscrew the oil cap then fill the oil until

reaching the limit of the oil gauge. Finally,

screw back the cylinder head stud.

Oil cap

Oil guide

groove

Oil cap

8

Summary of Contents for PM13000D ES OPEN

Page 1: ...DIESEL GENERATOR PM13000D ES OPEN PM13000D ES SILENT OPERATOR MANUAL...

Page 2: ...nerator Set Assembly Components 2 2 1 PM13000D ES Open Components 2 2 2 PM13000D ES Open Components 2 3 Inspection Before Operation 3 3 1 Checking and selecting your engine oil 3 3 2 Selecting and che...

Page 3: ...osed flush thoroughly with water and get immediate medical attention Charge the battery in a fully ventilated place Make sure battery polarity is correct OTHER SAFETY PRECAUTIONS Parts become hot when...

Page 4: ...2 Generator Set Assembly Components 2 1 PM13000D ES Open Components 2 2 PM13000D ES Silent Components 2 2...

Page 5: ...pe it with a rag or paper towel then dip it into the filter neck and pull it back out Add engine oil if the liquid is at or below the lower limit Take care not to add oil beyond the upper limit After...

Page 6: ...l injection pump and nozzle problems Refuel in a well ventilated area with the engine stopped Keep smoke flames or sparks away from fuel both when stored and refueling Do not overfill the tank and mak...

Page 7: ...ry settings 5 2 Checks during operation Any abnormal sound or vibration The engine misfiring or running rough What about the color of the exhaust gas is it black or too white If you notice any abnorma...

Page 8: ...ces e g Aircon b Set the AC breaker to OFF c Unplug the sockets of the electric appliances from the AC output port or extension cord d Let the engine run for 3 minutes with no load e Turn off the gene...

Page 9: ...Promate Service Proper maintenance is not only the basis of safe economical and trouble free generator operation but also helps reduce air pollution Maintenance Schedule Shut off the engine before pe...

Page 10: ...f the oil gauge Finally screw back the cylinder head stud 7 1 b Changing engine oil PM13000D ES Silent Open the left door use a wrench to release the drain plug don t take out the screw put the oil gu...

Page 11: ...running let it cool for 2 hours then clean the surface paint damaged areas and coat with a thin layer of plastic film textile or fabric Fuel Diesel fuel deteriorates during storage which will make st...

Page 12: ...8 Specifications 10 230 230 50...

Page 13: ...with the instructions and recommendations of the Company set forth in the owner s manual or if the product is used as rental equipment The Company will not pay for repairs or adjustments to the produc...

Reviews: