28
8.3 SERVICING THE AIR CLEANER
Operating engine with loose or damaged air cleaner components could
cause premature wear and failure. Replace all bent or damaged
components.
NOTE:
Paper element cannot be blown out with compressed air.
1. Remove precleaner from paper element.
2. Replace or wash precleaner in warm water with detergent. Rinse and allow to
air dry.
3. Saturate precleaner with new engine oil; squeeze out excess oil.
4. Reinstall precleaner over paper element.
1. Clean area-around element. Remove wing nut,element cover, and paper element
with precleaner.
2. Separate precleaner from element; service precleaner and replace paper element.
3. Check condition of rubber seal and replace it if necessary.
4. Install new paper element on base; install precleaner over paper element; reinstall
element cover and secure with wing nut.
Reinstall air cleaner cover and secure with knob.