MCU via above mentioned virtual COM port. 

 

(Same as running the general COM port)    This is a fast way else you are able to develop the 

application program using by Winsock.    Please refer to 

Chapter 7

 if you are developing a new 

program.    You have to understand what the format is especially for Ethernet package.     

 

In addition WEC200 features a service code formatted in unduplicated within every device.    This 

so-called service code serves the function of self check-up to ensure the software works for the right 

user while developing the software.     

 

WEC200 is working under LAN base; it will help a lot with your work if you configure several devices of 

WEC200 in the network.    WEC200 can be identified with each machine IDs and Names.   

 

Wiegand interface applies 4-wire technology (V/G/D0/D1) for connection.    4-wire connection is a 

must have to short distance communication which is good enough but to long distance wiring will be 

too much trouble.    We suggest applying 2 WEC200 to serve as the extension Wiegand interface tool.   

One device should be set up as a receiver the other should be set up as a transmitter.    The two 

WEC200 devices need to set up the matching IP to each other.    The two WEC200 will transmit from 

Wiegand reader accordingly over LAN network. 

 

3. Installation 

Connection in LAN 

A.  Connect WEC200 RJ45 jack to HUB/SWITCHING HUB 

correctly

 

with cable 

WAS-1499

.   

B.  Attach the Wiegand reader to CN2-L35005-T01-G and plug 

into WEC200 

C.  Attach the input/output device to CN2-L35010-T01-G and 

plug into WEC200. 

D.  Plug the power supply of the DC transformer into the Jack 

Panel of WEC200 (refer to 4-C as below) 

 

 

4. Pin Assignment 

4-A. RJ45 

Pin# 

Signal 

TX+(Positive line of the differential output signal 

pair) 

TX-(Negative line of the differential output signal 

Summary of Contents for WEC200

Page 1: ...tion Chapter 3 Installation Chapter 4 Pin Assignment Chapter 5 How to integrate with Access Control Chapter 6 Protocol Chapter 7 Communication Ethernet Module Chapter 8 Specification Appendix A LED2 S...

Page 2: ...Code and Card Code directly If your computer is equipped with one RJ45 port you are able to connect the 10 100BaseT Ethernet and support TCP IP UDP with your Wiegand reader through WEC200 Featuring of...

Page 3: ...0 D1 for connection 4 wire connection is a must have to short distance communication which is good enough but to long distance wiring will be too much trouble We suggest applying 2 WEC200 to serve as...

Page 4: ...hich is fail LED1 Green normally displays the status of the Ethernet Port When receiving an Internet package the LED1 will be cut off temporarily until the package is received entirely 4 C DC JACK Pin...

Page 5: ...closed N C What is N O It means when deactivation is appearing the status for the electric lock is unlock otherwise if activation is appearing for the electric lock the status will be switched to lock...

Page 6: ...least for the power supply WEC200 itself is causative which its consumable current stays at 150mA The running electric locks on the market exceed in this value widely In order to prevent the power co...

Page 7: ...Please refer to the example we illustrate Applying a separate power supply at DC12V output which is good enough to supply the power requirement for both of electric lock and alarm The part of lock is...

Page 8: ...ware Number V Version Y Revision For example STX ROM0722A7 CR 6 B Get service code HOST to DEVICE 4 bytes STX G S CR 02H 47H 53H 0DH DEVICE to HOST 12 bytes STX XXXXXXXXXX CR You can get the unique se...

Page 9: ...o HOST 3 bytes STX X CR You can get the type with this command X 0 receive only 1 transmit only default 6 G Get format status HOST to DEVICE 4 bytes STX G F CR 02H 47H 46H 0DH DEVICE to HOST 3 bytes S...

Page 10: ...s n 255 relay 1 keeping in close status 6 K Set relay2 output status HOST to DEVICE 5 bytes STX S A n CR 02H 53H 41H byte 0DH DEVICE to HOST 3 bytes STX ACK NACK CR You can activate relay2 n 0 1s stat...

Page 11: ...status a string data will go automatically by STX C CR to give you the notice of input is changing due to 0 1 s has detected itself It implied that several messages might send out already After receip...

Page 12: ...band UDP T inband TCP or command phase TCP e error status no errors detected E running in the error mode i IP address status not obtained yet I obtained via DHCP M fixed set manually c data connectio...

Page 13: ...Data _ A0 2 3 5 0 62 192 168 100 216 Note 1 This is a broadcasts command so the remote host IP needs to be set to 255 255 255 255 2 The default password is blank 3 For more details please refer to the...

Page 14: ...k1 RemoteHost 192 168 100 216 Winsock1 SendData PS01 Note 1 For more details please refer to the on line help file of DS Manager tibbo_docs chm on Set I O Pin Status Sx instruction section 7 B Reply C...

Page 15: ...consumption 140mA 12VDC Protocols Communicates with server on the networking using TCP or UDP protocols Indication type Three LEDs display status information One built in buzzer 2 sets of input 2 set...

Page 16: ...nection TCP or UDP with any network host is currently established Sending ARP Displayed when the DS is sending ARP requests to find out the MAC address of the destination network host with which the D...

Page 17: ...S S S C C C C C C C C C C C C C C C C P P E E E E E E E E E E E E O O O O O O O O O O O O P Summed for even parity E Summed for odd parity O Wiegand interface 30 bit format 1 2 3 4 5 6 7 8 9 10 11 12...

Page 18: ...O O O O O O O O O O O P Summed for even parity E Summed for odd parity O Wiegand interface 38 bit format 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35...

Page 19: ...EC200 00 and WEC200 01 To detail this for example if the tag code is FC177ID25111 then for WEC200 00 it will be packaged as Hex 02h 57h 46h 43h 31h 37h 37h 49h 44h 32h 35h 31h 31h 31h 0Dh W F C 1 7 7...

Page 20: ...U program This chapter doesn t open all the commands Only list some of them that customer may use Reboot Description Reboot the WEC200 01 device Command Hex 05h 54h 45h 1Ah T E The command package sta...