PROMAG
DF7XX
REV.C
12
Enable Two Wires Control LED / Disabled ABA-TK2: (For 19200,n,8,1 only)
set up the "Brown Wire Active Level", and Brown wire and Orange wire will follow
the setting.
Example: "Brown Wire Active Level"=High; Green light on with a beep when brown
wire level was high. Red light on with three beeps when orange wire level high.
When both wire change level high at the same time, it will both light on without
beep.
Read Idle:
Show LED color after power on or idle state.
Brown wire = PULSE (or Card is valid):
Show LED color and beeps to indicate the end-user when
brown wire = PULSE, or card was passed by DF7XX Reader.
Brown wire = Inactive (or Card is invalid):
Show LED color and beeps to indicate the end-user when
brown wire = Inactive, or card was failed by DF7XX Reader.
Brown wire = Active:
Show LED color and beeps to indicate the end-user that brown wire = Active signal
from Host.
Brown wire Active level:
Set Brown wire Active level condition with Host status.
Disable: Always disable the Brown wire. (Default), LED/Buzzer controls by reader self.
High: Active High / Normal keep in Low.
Low: Active Low / Normal keep in High.
Remark:
If set Active Low, you may have to connect brown wire to a pull-up resistor (1K~10K) with 5VDC)
.
Control Brown wire:
After Data Output: The brown wire will be enabling after finished output the card data or CSN. (Default)
Any Time: The brown wire enabled in any time.
Note: See Annex E, the LED/Buzzer also can be controlled externally with High/Low
level control.
Brightness:
Change value to brighten or darken led. More high and more brighten..