Proluxe DP330M Operation Manual Download Page 8

 

depressing button. 
 

controller until button activate. 
Same goes in reverse if buttons 
are held down by the overlay. 
 

Digital display shows 
relay and particular 
zone is overheating.  

1.  The relay on the switched side is 
not opening to regulate temperature. 
 

1.  Replace the relay. 

92 

Beeper not 
functioning or 
intermittent beeper 
sound. 

1.   Beeper on digital control board 
failed. 

1.   Replace digital controller 
board 

85 

Power is on but hear 
a leaking of air under 
the lower platen / 
swing arm while 
press is idle. 

The O'rings are worn allowing the air 
to pass through the cylinder 

The cylinder needs o-rings, 
gasket 
and new cylinder grease. Request 
instruction sheet and need to 
order P/N 110033 for the kit. 
 

---- 

Press does not close 
when pressing the 
two, green, start 
buttons 

Did not simultaneously press the 
start buttons exactly at the same 
time. 

Try pressing both buttons exactly 
at the same time. This is a 
anti-tiedown safety feature. 

If setpoint is reached 
but slightly off in 
temperature. 

Offset may need to be calibrated and 
adjusted. 

Call (800) 624-6717 ext. 129 for 
instructions. 

---- 

After activation 
lower platen and 
when the cycle is 
complete, the lower 
platen either is very 
slow coming down or 
doesn’t come down 
at all. 

The Mufflers on the Solenoid Valve 
are dirty and now allowing air from 
passing though. 
 

Replace both Solenoid Valve 
mufflers. 
 

---- 

Upon activation, the 
lower platen is slow 
to come up and 
down. 

Filter encased in a black housing in 
the back of the machine is dirty. 
 

Replace filter. 

--- 

Heater platens 
overheating 

If the relay (depending on the year of 
the model) on the coil side are 
receiving 12vdc indicates the 
controller is functioning properly. On 
the switching side of the relay, is 
there 120 vac going to the heater in 
question. If there is no voltage on 
the to the switching side of the relay 
to the heaters, the relay is not 

Replace relay If the controller's 
heat-on LED is not lit indicating 
the controller is working 
properly. 
 

92 

Summary of Contents for DP330M

Page 1: ...Operations Manual Impact X1M Electro mechanical Automatic Dough Press w Embedded Mold Model DP3300M WWW PROLUXE COM Version 51219...

Page 2: ...re is a proper electrical wall outlet located within reach of the cord and plug attached to the press Place the press in an area which allows for swing clearance of the lower platen plus vertical and...

Page 3: ...ing hot surfaces while operating the machine Caution During normal operation the base of the machine must be installed or placed above the wall socket When servicing or cleaning the machine make sure...

Page 4: ...ng Temperature Press MODE button until temperature is displayed Press and hold SET button while pressing the UP and DOWN arrow buttons to desired temperature setting Fahrenheit Celsius Conversion The...

Page 5: ...gh in the approximate center of the lower platen mold Add another spray to the top of the dough ball 6 Close the platen and with both hands press the two green buttons on the machine simultaneously 7...

Page 6: ...press piston it is important that the machine be lubricated once every three months under normal operation High volume users may require more frequent lubrication Please follow these instructions 1 Lo...

Page 7: ...t go to segment check 1 Possibly a component on the Digital controller is damaged 2 Control needs to reset 1 Replace digital controller 2 While unit is on unplug unit wait for 1 min Then plug machine...

Page 8: ...the same time This is a anti tiedown safety feature 2 If setpoint is reached but slightly off in temperature Offset may need to be calibrated and adjusted Call 800 624 6717 ext 129 for instructions A...

Page 9: ...working properly 8...

Page 10: ...9...

Page 11: ...10...

Page 12: ...11...

Page 13: ...83214 9 12 FEET RUBBER RF209 RF209 RF209 RF209 RF209 RF209 RF209 4 13 LOWER PLATEN STOP W WASHER 110102130 110102130 110102130 110102130 110102130 110102130 110102130 1 14 WASHER SAE 3 8 WSAE38 WSAE38...

Page 14: ...086074 11086074 1 40 BOLT LEVEL ADJUSTMENT 1109367 1109367 1109367 1109367 1109367 1109367 1109367 4 41 BOLT HEX 5 16 18 x 1 3 4 GR5 BH51618134 G5 BH51618134 G5 BH51618134 G5 BH51618134 G5 BH51618134...

Page 15: ...WASHER SPLIT LOCK 8 WSL8 WSL8 WSL8 WSL8 WSL8 WSL8 WSL8 4 70 BRACKET MICRO SWITCH THICK THIN 11072080 11072080 11072080 11072080 11072080 11072080 11072080 1 71 SCREW ROUND HEAD 4 40 X 5 8 SLOTTED SR44...

Page 16: ...R 6 INTERNAL TOOTH LOCK WLIT6 WLIT6 WLIT6 WLIT6 WLIT6 WLIT6 WLIT6 8 99 NUT HEX 6 32 NH632 NH632 NH632 NH632 NH632 NH632 NH632 8 100 BUTTON BLACK MUSHROOM P9ARB3N P9ARB3N P9ARB3N P9ARB3N P9ARB3N P9ARB3...

Page 17: ...16...

Page 18: ...any of its products if operated improperly or caused by normal wear or damaged by operator abuse Limited Lifetime Warranty on Heating Elements If replacement is needed Proluxe will send the new part...

Page 19: ...e determined by Proluxe unless otherwise advised by purchaser 6 Damaged Claims All merchandise shipped at purchaser s risk Inspection must be made by purchaser at time goods are received If goods are...

Reviews: