Vantage Light Troubleshoot Guide - Model #: CS157
Problem
Cause
Action
Ref #
Power button on
digital controller face
is depressed but
doesn’t turn on.
1. Power cord is not plugged in.
2. Circuit breaker is tripped off in the
site's breaker box.
3. Transformer has taken an
electrical surge and is damaged.
4. Check the voltage on the
secondary side of the transformer. If
you read 12VDC then you are
receiving voltage to the controller.
5. Possible blown fuse.
1. Plug the power cord into wall
receptacle and power button.
2. Reset circuit breaker that the
grill is plugged into. Depress
Power Button to turn on.
3. Replace Transformer after you
check the secondary side of the
transformer. If working properly,
you should receive 12vdc.
4. Replace controller. Controller
should be on once the power
button is depressed.
5. Replace fuse.
----
-----
18
A8
98
Digital controller's
LED's are scrambled
or randomly erratic.
If when turning on,
the display will first
go to segment check
1. Possibly a component on the
Digital controller is damaged.
2. Control needs to reset.
1. Replace digital controller.
2. While the unit is on unplug unit,
wait for 1 min. Then plug machine
on again and depress the power
button.
A8
----
Digital controller is
constantly beeping.
No heat on either on
left, right, upper, or
lower platen.
Sensor in one of two zones lost its
continuity. Depress TEMP. While
depressing TEMP depress either up
or down arrow to locate error
message PROB (zone 1, lower
platen, zone 2 left upper platen, zone
3, right upper platen.) If occurred
when depressing the up arrow
indicates either the left or right
platen has the open sensor or
Probe.
Disconnect probe and check for
continuity (by using Ohm Meter)
and replace. Do not cut and splice
new sensor. Install new 2000
ohm RTD sensor to underside of
the platen and reconnect to
controller. Upper left and right
sensor for replacement on upper
platens, lower platen sensor for
replacement for lower platen.
22
46
Digital display shows
PROB. No heat on
any platen.
Sensor lost it's continuity as shown
on a muti-meter.
Disconnect prob that is open (no
continuity as shown on a multi-
meter. Must replace sensor
(RTD). Do not cut and splice new
sensor. Install a new 2000 ohm
RTD sensor to under side of heat
41