Proluxe CS157TBA Operation Manual Download Page 5

Vantage Light Troubleshoot Guide - Model #: CS157 

 

 

Problem 

Cause 

Action 

Ref # 

Power button on 
digital controller face 
is depressed but 
doesn’t turn on. 

1.   Power cord is not plugged in. 
 
 
2.  Circuit breaker is tripped off in the 
site's breaker box. 
 
 
3.  Transformer has taken an 
electrical surge and is damaged. 
 
 
4.  Check the voltage on the 
secondary side of the transformer. If 
you read 12VDC then you are 
receiving voltage to the controller. 
 
5.  Possible blown fuse. 

1. Plug the power cord into wall 
receptacle and power button. 
 
2. Reset circuit breaker that the 
grill is plugged into. Depress 
Power Button to turn on. 
 
3. Replace Transformer after you 
check the secondary side of the 
transformer. If working properly, 
you should receive 12vdc. 
 
4. Replace controller. Controller 
should be on once the power 
button is depressed. 
 
5. Replace fuse. 

 
---- 
 
 
----- 
 
 
 
18 
 
 
 
 
A8 
 
 
98 

Digital controller's 
LED's are scrambled 
or randomly erratic. 
If when turning on, 
the display will first 
go to segment check 

1.  Possibly a component on the 
Digital controller is damaged. 
 
2. Control needs to reset. 

1. Replace digital controller. 
 
 
2. While the unit is on unplug unit, 
wait for 1 min. Then plug machine 
on again  and depress the power 
button. 
 

A8 
 
 
 
---- 

Digital controller is 
constantly beeping. 
No heat on either on 
left, right, upper, or 
lower platen. 
 
 
 

Sensor in one of two zones lost its 
continuity. Depress TEMP. While 
depressing TEMP depress either up 
or down arrow to locate error 
message PROB (zone 1, lower 
platen, zone 2 left upper platen, zone 
3, right upper platen.) If occurred 
when depressing the up arrow 
indicates either the left or right 
platen has the open sensor or 
Probe. 
 

Disconnect probe and check for 
continuity (by using Ohm Meter) 
and replace. Do not cut and splice 
new sensor. Install new 2000 
ohm RTD sensor to underside of 
the platen and reconnect to 
controller. Upper left and right 
sensor for replacement on upper 
platens, lower platen sensor for 
replacement for lower platen. 
 

22 
46 

Digital display shows 
PROB. No heat on 
any platen. 
 

Sensor lost it's continuity as shown 
on a muti-meter. 

Disconnect prob that is open (no 
continuity as shown on a multi- 
meter. Must replace sensor 
(RTD). Do not cut and splice new 
sensor. Install a new 2000 ohm 
RTD sensor to under side of heat 

41 

Summary of Contents for CS157TBA

Page 1: ...Operations Manual Vantage Light Single Lid Clamshell Grill Model CS157TBA WWW PROLUXE COM Version 51719...

Page 2: ...ace in a location where it will be used allowing for clearances per the dimensions indicated Allow 2 minimum clearance between adjacent equipment and or wall areas 2 Plug into proper 3 prong wall outl...

Page 3: ...timer you can manually adjust the left side timer without affecting the right timer C L E A N C Y C L E Start Cycle To start a clean cycle push CLEAN button once so the CLEAN LED light is turned on A...

Page 4: ...ft sponge 2 Exterior surfaces Wipe daily with mild soap and warm water DO NOT use ice or cold water to cool the unit down This can cause platens to warp Service Problems Contact our factory at 800 624...

Page 5: ...maged 2 Control needs to reset 1 Replace digital controller 2 While the unit is on unplug unit wait for 1 min Then plug machine on again and depress the power button A8 Digital controller is constantl...

Page 6: ...shade of toast Call 800 624 6717 for instructions One heating zone is not reaching setpoint and another heater is overheating Sensors maybe crossed Make sure each sensor is connected to its prospectiv...

Page 7: ...lost tension The springs have lost some tension Remove rear panel and adjust the retaining collars on shaft by winding the spring tighter There are multiple set screws that need to be loosened in orde...

Page 8: ...7...

Page 9: ...8...

Page 10: ...9...

Page 11: ...03903 1 14 GREEN INSULATION WASHER C4401 C4401 C4401 9 15 TOP LINK 110115508 110115508 110115508 1 16 BOLT HEX 5 16 18 X1 STAINLESS STEEL BH516181S BH516181S BH516181S 2 17 E CLIP RETAINING RING LCC34...

Page 12: ...SPS103238S SPS103238S 6 50 SCREW SOCKED HEAD 5 16 18 X 3 4 SSH5161834 SSH5161834 SSH5161834 3 51 SCREW SET 3 8 16 X 1 2 SST381612 SST381612 SST381612 3 52 SCREW PAN HEAD PHILLIPS 6 32 X 1 4 SP63214 SP...

Page 13: ...157 MSCS157 1 88 SCREW SET 3 8 16 X 1 1 2 SST3816112 SST3816112 SST3816112 4 89 TRANSFORMER INSULATION 1101159180 1101159180 1101159180 1 90 SCREW PHILLIPS 6 32X5 8 SP63258 SP63258 SP63258 2 91 LOWER...

Page 14: ...13...

Page 15: ...accident Improper or unauthorized repairs Submerged in water Damaged in shipment Equipment exported to foreign countries Special Order Equipment and Accessories Cannot be canceled and are not returna...

Page 16: ...s will be made C O D Cash in advance 4 Pricing Prices specifications model numbers capacities and accessories are subject to change without notice 5 F reight Routing Method of shipment will be determi...

Reviews: