Proluxe CS157TBA Operation Manual Download Page 3

 
To find the temperature of bottom platens: 
Press and hold the TEMP button and the 
arrow down (

) button at the same time. 

 
Adjusting the Set Temperature

 

1. Press and hold the TEMP button and 

the arrow up (

) button at the same 

time for 15 seconds. 
 

2. The current temperature with display 

on the right digital display screen 
only. 
 

3. Using the up (

) and down (

) adjust 

the temperature to your desired 
setting. 
 

4. Once your desired temperature is 

set, push the TEMP button to return. 

 

Adjusting the Set Time

 

1. Press the TEMP button first and then 

select the desired timer button and 
hold for 5 seconds. 
 

2. The current temperature with display 

on the right digital display screen 
only. 
 

3. Using the up (

) and down (

) adjust 

the timer to your desired setting. 
 

4. Once your desired temperature is 

set, push the TEMP button to return. 

 
Note

: When adjusting the timer settings, the 

right set of buttons control the left side. 
Your left side timer will automatically set to 
your right control settings. If you desire a 
separate left timer you can manually adjust 

the left side timer without affecting the right 
timer. 
 
 
C L E A N   C Y C L E 

 
Start Cycle

 

To start a clean cycle, push CLEAN button 
once so the CLEAN LED light is turned on. All 
preset LED’s are turned off, and the 
temperature set point is changed to the clean 
set point of 275°F. This also initiates the cool 
down to clean set point condition as well the 
display starts flashing until the clean set 
point is reached. 
 

Stop Cycle 

To stop the clean cycle, simply press the 
CLEAN button once to deactivate the clean 
cycle. The CLEAN LED is turned off, the 
preset LED’s are restored, the temperature 
set point is changed to the main set point. 
Again, the warm-up condition is initiated and 
the display flashes until the cook set point is 
reached. 
 

Change Clean Temp

 

275°F is the factory default temp for the 
CLEAN cycle. To change the CLEAN cycle 
temp, simultaneously hold down the TEMP 
and CLEAN buttons for 15 seconds. The 
current temp setting will display on the right 
digital display only. Using the up or down 
arrows to adjust to the desired temp. 

 
 
P R E V E N T A T I V E   
M A I N T E N A N C E   

 
Proluxe machines are relatively 
maintenance-free. For a long lifespan, the 

Summary of Contents for CS157TBA

Page 1: ...Operations Manual Vantage Light Single Lid Clamshell Grill Model CS157TBA WWW PROLUXE COM Version 51719...

Page 2: ...ace in a location where it will be used allowing for clearances per the dimensions indicated Allow 2 minimum clearance between adjacent equipment and or wall areas 2 Plug into proper 3 prong wall outl...

Page 3: ...timer you can manually adjust the left side timer without affecting the right timer C L E A N C Y C L E Start Cycle To start a clean cycle push CLEAN button once so the CLEAN LED light is turned on A...

Page 4: ...ft sponge 2 Exterior surfaces Wipe daily with mild soap and warm water DO NOT use ice or cold water to cool the unit down This can cause platens to warp Service Problems Contact our factory at 800 624...

Page 5: ...maged 2 Control needs to reset 1 Replace digital controller 2 While the unit is on unplug unit wait for 1 min Then plug machine on again and depress the power button A8 Digital controller is constantl...

Page 6: ...shade of toast Call 800 624 6717 for instructions One heating zone is not reaching setpoint and another heater is overheating Sensors maybe crossed Make sure each sensor is connected to its prospectiv...

Page 7: ...lost tension The springs have lost some tension Remove rear panel and adjust the retaining collars on shaft by winding the spring tighter There are multiple set screws that need to be loosened in orde...

Page 8: ...7...

Page 9: ...8...

Page 10: ...9...

Page 11: ...03903 1 14 GREEN INSULATION WASHER C4401 C4401 C4401 9 15 TOP LINK 110115508 110115508 110115508 1 16 BOLT HEX 5 16 18 X1 STAINLESS STEEL BH516181S BH516181S BH516181S 2 17 E CLIP RETAINING RING LCC34...

Page 12: ...SPS103238S SPS103238S 6 50 SCREW SOCKED HEAD 5 16 18 X 3 4 SSH5161834 SSH5161834 SSH5161834 3 51 SCREW SET 3 8 16 X 1 2 SST381612 SST381612 SST381612 3 52 SCREW PAN HEAD PHILLIPS 6 32 X 1 4 SP63214 SP...

Page 13: ...157 MSCS157 1 88 SCREW SET 3 8 16 X 1 1 2 SST3816112 SST3816112 SST3816112 4 89 TRANSFORMER INSULATION 1101159180 1101159180 1101159180 1 90 SCREW PHILLIPS 6 32X5 8 SP63258 SP63258 SP63258 2 91 LOWER...

Page 14: ...13...

Page 15: ...accident Improper or unauthorized repairs Submerged in water Damaged in shipment Equipment exported to foreign countries Special Order Equipment and Accessories Cannot be canceled and are not returna...

Page 16: ...s will be made C O D Cash in advance 4 Pricing Prices specifications model numbers capacities and accessories are subject to change without notice 5 F reight Routing Method of shipment will be determi...

Reviews: