Q3: Will reversing polarity connections of the jump start cable damage the vehicle?
A3: Not at all, the MCL -007 is very safe with „Reverse Polarity Protection“. lf you accidentally connect the
RED and BLACK cable clamps to the wrong polarity terminal and attempt to jump start the vehicle, the
ingenious spark-proof clamp (the red indicator light is on) will cut the power immediately to prevent
injury and avoid damaging the vehicle.
Q4: What if it doesn‘ t jump start the vehicle?
A4: lf the MCL-007 fails to jump start the engine, please wait at least 10 seconds before attempting to try
again and please do not continuous cranking for over 5 seconds each time. lf still not succeed after
3 attempts, it may be due to other problems of the vehicle. Do not try to crank the engine continuously
for more than 10 times in a row. lt is also highly recommended to replace the vehicle battery once every
2-3 years.
Q5: How many times can the MCL-007 jump start a vehicle?
A5: Approximately 10 times with a 100% fully charged battery. Results may vary depending on user usage
and vehicle engine displacement.
Q6: How long is the MCL -007 standby time?
A6: The standby time of the MCL-007 is up to 6 months if it is fully charged. lt is recommended to charge
the MCL-007 every 3 months to prolong its service life. Result may vary depending on the owner usage.
Q7: How long will it take to fully charge the MCL-007 to the maximum battery level?
A7: lt takes about 5-6 hours through the 5V/2A input port.
Q8: How long will it take to fully charge a mobile phone?
AB: lt will take about 1 hour.
TROUBLE SHOOTING
PROTECTION
- Overcharge anc Overdischarge Protection
- Explosion-proof
- Agalnst-reverse Plug
Finding
Cause
Remedies
The indicator light is off on the
lngenious Spark -proof clamps
controller after connecting to the
vehicle battery.
The vehicle battery is either at
ZERO volt or is not connected with
a battery.
Make sure the battery is fully
charged and then reconnect the
lngenious spark-proof clamps
Takes over 10 hours to recharge
the MCL-007.
lncorrect AC adaptor being used to
recharge lheMCL-007.
Recommended to recharge it by
2A output USB adaptor.
There is no response when press
the Power button an the MCL -007.
The low voltage protection is
activated and the electronic circuit
has been shut off.
Plug the chargmg adapter into
the charging port to activate the
electronic circuit.