Prolitec AirQ AQ 1270 TT Original Instructions Manual Download Page 26

AQ/PS/RZ  1270

26

Chapter 10    

INSTALLATION: DIffusion via Direct Indoor Fan

Diffusion Fan Installation 

                      Fig. 3                                   Fig. 4                                           Fig. 5                                              Fig. 6

1.  The diffusion fan is positioned directly above the appliance hose output port located on the top 

left of the appliance but no more than 4-1/2 feet above it. (

Fig. 3

)

2.  Use the diffusion fan assembly as a template to mark the location of the mounting holes. (

Fig. 4

)

3.  For installation on drywall, drill the 3 anchors into drywall and install the 3 screws to secure 

the diffusion fan to the wall. Use the metal screws provided for installation on sheet metal or 
appropriate fastening hardware for other wall surfaces. (

Figs. 5 & 6

)

4.  Verify cable connection with diffusion fan. (

Fig. 7

5.  Measure the length of cable raceway needed and cut to length using a pair of scissors or a 

cutting blade (

Fig. 8

).  Fold into an “L” shape and peel off liner (

Fig. 9

).  Fasten adhesive side to 

the wall between appliance and Diffusion Fan assembly. 

Fig. 7

10

Summary of Contents for AirQ AQ 1270 TT

Page 1: ...AQ PS RZ 1270 TT WM PERFECTLY SCENTED ENVIRONMENTS Original Instructions Rev 2016 04 12...

Page 2: ...ool Setting Scent Intensity Scent Control Chapter 9 INSTALLATION Diffusion via HVAC system Installation Kit for Appliance Installation Kit for HVAC System DIffusion HVAC Pre installation Checklist App...

Page 3: ...ling and ambient scenting in public spaces such as casinos malls hotels theaters ballrooms convention centers hospitals retirement and assisted living facilities schools and restrooms A single AQ1270...

Page 4: ...e is easy to read It is also important to read AQ1270 is a high performance appliance that installed and used correctly will meet the most demanding requirements Table 1 Prolitec AirQ Technology vs Ae...

Page 5: ...d be included 1 AQ1270 Appliance 2 HVAC kit 3 Plume kit MOVING AND STORAGE INSTRUCTIONS 1 Remove the cartridge 2 Unscrew and remove the long round head screws in the lower corners 3 Lift the appliance...

Page 6: ...47100 849 1333 75000 97100 2123 2748 11 15 19300 27700 546 784 51100 66300 1446 1876 101100 114000 2861 3226 16 20 30000 39700 849 1124 70000 83600 1981 2366 116700 125100 3303 3540 21 25 42300 53400...

Page 7: ...upper respiratory discomfort This appliance is not intended for use by persons with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supe...

Page 8: ...ge to avoid the liquid getting on hands The AirQ fragrances are formulated so as to not be harmful in contact with the skin but the concentrated nature of the fragrances may make the scent difficult t...

Page 9: ...9 Chapter 6 Appliance Controls Appliance Controls 6 Screw Cap Tube Connector Air Nozzle Recyclable Cartridge First Stage Air Filter Control Display Control Buttons Battery Tab Injector Hose Auxiliary...

Page 10: ...from the cartridge output port and pulling out 5 Remove cartridge from appliance enclosure 6 Install new cartridge place and tighten hose connector firmly on cartridge output port 7 Insert air nozzle...

Page 11: ...lter should be replaced To replace it unscrew the 3 knobs to open the panel and exchange the filter after pulling off the rubber tubing from both sides of the filter Note the small triangle showing th...

Page 12: ...met The battery is located on the lower front corner of the silver bracket Insert the new CR2032 battery The positive side of the battery should face your right while looking at the front of the appli...

Page 13: ...our modes using E or F Press L to set the time mode and the off cycle will blink Change between normal NOC 7 minutes short SOC 2 minutes and very short VSOC 30 seconds modes using E or F Press L to se...

Page 14: ...the stop hour forward or backward using E or F Press L to set the stop hour and the minute will blink Adjust the stop minute forward or backward using E or F Press L to set the step minute The applia...

Page 15: ...32 Copy the files needed schedule txt for programs discover hex for firmware to the top level directory of the card not in a folder or zip file 7 Insert the SD card into the appliance with the label s...

Page 16: ...view the second and third programs 13 Be sure the power is on and the appliance is in RUN PROGRAM mode prior to closing and locking the door Copying programs to an SD card 1 Insert a FAT32 formatted S...

Page 17: ...st of all user preferences Experiment with different levels until you are satisfied Utilize the S3 Tool Scent Control If you followed the Room Size Table or S3 Tool you have set AQ1270 to the low end...

Page 18: ...270 appliance not pictured with 2 Four 4 drywall anchors for mounting in drywall 3 Four 4 lead anchors for mounting in concrete 4 Four 4 screws and 4 washers for mounting in drywall and concrete 5 Fou...

Page 19: ...install date 1 Confirm the area to be targeted for air treatment 2 Determine the Air Handling Unit or duct that serves the target area 3 Make sure the AHU does not use an open gas flame 4 Find and ma...

Page 20: ...er steam chilled water and DX coils Open gas flames should absolutely be avoided If installation must be over gas heated coils or open gas flames contact Prolitec Technical Support The best location f...

Page 21: ...AC plug to the cord and connect to a nearby outlet Open the enclosure door and unscrew the aluminum cap of the waterproof collar located on top of the appliance enclosure Remove and set aside the gro...

Page 22: ...section of duct and far away from any turns branches or cross section changes as practical and not immediately after the supply fan 1 At the insertion point drill a hole using a drill bit 2 Insert th...

Page 23: ...uded 1 One 1 AQ1270 appliance not pictured with 2 Four 4 dry wall anchors for mounting in drywall 3 Four 4 lead anchors for mounting in concrete 4 Four 4 screws and 4 washers for mounting in drywall a...

Page 24: ...One 1 Prolitec Diffusion fan and cable for direct indoor diffusion 2 Three 3 drywall anchors for mounting fan onto dry wall 3 Three 3 lead anchors for mounting in concrete 4 Three 3 screws for mountin...

Page 25: ...Place the appliance onto the desired location on the wall and ensure that it is level 2 Fasten the appliance to the wall using the necessary anchors screws and washers provided 3 Open the enclosure d...

Page 26: ...ng holes Fig 4 3 For installation on drywall drill the 3 anchors into drywall and install the 3 screws to secure the diffusion fan to the wall Use the metal screws provided for installation on sheet m...

Page 27: ...11 If needed use a flat head screw driver to push in the side wall of the cable raceway Fig 12 Fig 13 Fig 14 7 Insert cable connector into jack located on the right side of the appliance Fig 12 8 Ext...

Page 28: ...ace Increase the output rate by one or two settings and evaluate detection in 30 minutes Repeat as needed If consumption requires cartridge change more frequently than each month install an additional...

Page 29: ...t tube Check and remove it The air intake may be blocked Another method for clearing obstructions is while the appliance compressor is running block the output tube with a finger for a few seconds and...

Page 30: ...not paint or otherwise try to alter the color of the outer cover Always keep the cap and plug on cartridges when stored outside of the AQ1270 Do not operate AQ1270 in very dusty areas that may cause...

Page 31: ...ll as auditory elements like music With ambient scenting a carefully selected fragrance is used to enhance themes animate visuals make a tree or a flower smell like a tree or a flower and many other u...

Page 32: ...eat the surrounding air space with the scent that is being advertised on the billboard This is particularly effective in high traffic areas such as malls airports and train and subway stations This is...

Page 33: ...d customer service and overall improved productivity AQ1270 and Prolitec aromatherapy chemistry can help make a workspace a more comfortable and appealing place to be As examples of the positive effec...

Page 34: ...or table top Do I need to adjust AQ1270 Yes AQ1270 is a powerful machine AQ1270 can handle small and very large rooms If it is set too high for the room size it can cause discomfort for some people Ad...

Page 35: ...nlike many air fresheners AQ1270 uses no ethanol or similar solvents to enhance the evaporation of fragrance chemicals I only want to scent the room at certain times Do I have to turn it on and off ev...

Page 36: ...Frequency 50 60 Hz Protection Switching power supply Internal Power 15V DC at 1 2 A Battery Lithium 3V CR2032 Approvals FCC part 15 CE RoHS UL Power Supply Working Temperature 0 to 40 C Working Humid...

Reviews: