15
Chapter 8
OPERATING INSTRUCTIONS
• The tool will warn the user of overlapping programs.
• Programs sets need to be saved.
3. Edit an existing program set using the
EDIT
button to the right of the program name.
4. Copy an existing program set using the
COPY
button to the right of the program name. This can
be especially useful for quickly duplicating a very similar set of programs.
5. Delete an existing program set using the
DELETE
button to the right of the program name.
6. Export an existing program set using the
EXPORT
button to the right of the program name.
• A .zip file containing your program set (schedule.txt), the latest firmware (discover.hex), and
the final instruction for use (readme.txt) will download to your computer.
• Insert an SDHC card and format it FAT32.
• Copy the files needed (schedule.txt for programs, discover.hex for firmware) to the top level
directory of the card (not in a folder or .zip file).
7. Insert the SD card into the appliance, with the label side down.
Loading new firmware from an SD card
1. Copy discover.hex to a FAT32 formatted SD card.
2. Insert the SD card, with the label side down.
3. Press the reset button, and the five buttons will light in sequence
from left to right.
4. The
:
and
E
buttons will light alternately.
5. Press and hold
:
for one second, and the display will show
LOAD
for
about ten seconds.
6. The five buttons will light in sequence from left to right.
7. Remove the SD card; the display will show the currently loaded firmware version and the pump
will run for one second.
8. Press
:
to turn on the power.
9. Be sure that the power is on and the appliance is in
RUN PROGRAM
mode prior to closing and
locking the door.
Programming the Appliance from an SD card
1. Copy schedule.txt to a FAT32 formatted SD card.
8