Installation
A. Operation:
The Air/Q 565 generates micro-droplets 1/100th the diameter of a
human hair from a reservoir of liquid in a disposable cartridge. These micro-droplets
behave like a vapor. They are passed through a silicon tube and injected into the
airflow of the air handler using an injector tube that is installed in a hole in the duct-
work. The micro-droplets blend with the air in the ducting to deliver a uniform effect
throughout the area served.
B. Airflow Switching:
The Air/Q 565 is operated
only when the fan or blower is operating to ensure
uniform, even distribution. To make this possible a
12V airflow switch is provided.
C. Determining the Location of Airflow Switch:
The airflow switch should be mounted vertically
on the side of the air duct at a convenient location
and downstream from the furnace.
Caution: Do
not mount airflow switch on return side.
The air-
flow switch and the female connector on the lower
right side of the Air/Q 565 appliance should be less
than 5 feet apart. The hose run to the Sensor Tube
should be as short as possible and less than 1 foot.
D. Positioning the Air/Q 565 Machine:
The Air/Q 565 machine is mounted on
a flat vertical surface — either a wall or on an air duct. The maximum run of the
silicon injector hose between the Cartridge and the Injector Tube is 18”. The short-
est possible run length is better. Be sure the hose is kept on a vertical incline, is not
crimped and does not sag. Therefore, the Air/Q 565 machine should be positioned
so the top left surface is no more than 1 foot from the injection point. It should be
easily accessible for servicing, and in proximity of an electrical power outlet.
8
Airflow switch