Hauser
• CAN/CSA-C22.2 No. 61010-1-04
Safety Requirements for Electrical Equipment for Measurement, Control and Laboratory Use - Part
1 General Requirements
• NAMUR NE 21
Electromagnetic compatibility (EMC) of industrial process and laboratory control equipment.
• NAMUR NE 32
Data Retention in the Event of a Power Failure in Field and Control Instruments with
Microprocessors
• NAMUR NE 43
Standardization of the signal level for the breakdown information of digital transmitters with
analog output signal.
• NAMUR NE 53
Software of field devices and signal-processing devices with digital electronics
• NAMUR NE 105
Specifications for Integrating Fieldbus Devices in Engineering Tools for Field Devices
• NAMUR NE 107
Self-monitoring and diagnosis of field devices
• NAMUR NE 131
Requirements for field devices for standard applications
Ordering information
Detailed ordering information is available from the following sources:
• In the Product Configurator on the Hauser website:
www.endress.com
→ Select country →
Instruments → Select device → Product page function: Configure this product
• From your Hauser Sales Center:
www.endress.com/worldwide
Product Configurator - the tool for individual product configuration
• Up-to-the-minute configuration data
• Depending on the device: Direct input of measuring point-specific information such as
measuring range or operating language
• Automatic verification of exclusion criteria
• Automatic creation of the order code and its breakdown in PDF or Excel output format
• Ability to order directly in the Hauser Online Shop
Application packages
Many different application packages are available to enhance the functionality of the device. Such
packages might be needed to address safety aspects or specific application requirements.
The application packages can be ordered from Hauser either directly with the device or
subsequently. Detailed information on the order code in question is available from your local Endress
+Hauser sales center or on the product page of the Hauser website:
Cleaning
Package
Description
Electrode cleaning circuit
(ECC)
The electrode cleaning circuit (ECC) function has been developed to have a solution
for applications where magnetite (Fe
3
O
4
) deposits frequently occur (e.g. hot
water). Since magnetite is highly conductive this build up leads to measuring errors
and ultimately to the loss of signal. The option is designed to AVOID build up of
highly conductive matter and thin layers (typically magnetite).