Proline Promag L 400
62
Hauser
Remote operation
Via HART protocol
1
2
3
5
7
4
6
A0017124
28
Options for remote operation via HART protocol
1
Control system (e.g. PLC)
2
Field Communicator 475
3
Computer with operating tool (e.g. FieldCare, AMS Device Manager, SIMATIC PDM)
4
Commubox FXA195 (USB)
5
Field Xpert SFX100
6
VIATOR Bluetooth modem with connecting cable
7
Transmitter
Via service interface (CDI-RJ45)
1
3
2
A0020481
1
Computer with Web browser (e.g. Internet Explorer) for accessing the integrated device Web server or with
"FieldCare" operating tool with COM DTM "CDI Communication TCP/IP"
2
Standard Ethernet connecting cable with RJ45 plug
3
Service interface (CDI -RJ45) of the measuring device with access to the integrated Web server
Via Ethernet network
This communication interface is present in the following device version:
Order code for "Output", option
N
: EtherNet/IP
Summary of Contents for Promag L 400