![Proline CVMP660W-1 Operating And Installation Instructions Download Page 10](http://html1.mh-extra.com/html/proline/cvmp660w-1/cvmp660w-1_operating-and-installation-instructions_1614854010.webp)
7
Before proceeding with the electrical connection, verify that the current carrying capacity of the
is adequate for the maximum power rating of the cooker.
Do not use adaptors, multiple sockets and/or extension leads.
Fused switch must be accessible once the
cooker
has been installed.
IMPORTANT: The following diameters of supply cable must be used at least in case of one
phase connection:
electrical supply
Connection diagram is given below.
3x2.5 mm 220V~
3x2.5 mm 230V~
3x2.5 mm 240V~
²
²
²
5x1.5 mm 380V 3N~
5x1.5 mm 400V 3N~
5x1.5 mm 415V 3N~
²
²
²
3.2 ADJUSTMENT OF FEET
Do not lift by pulling the oven door handle.
Your cooker stands on 4 adjustable feet. When the cooker is
placed where it will be used, check if the cooker is balanced. If
it is not balanced, you can make the adjustment by turning the
feet clockwise if required. It is possible to raise the appliance a
maximum of 30mm by the feet. If the feet are adjusted
appropriately, you should not move the appliance by dragging,
it should be moved by lifting it up.
PART 3: INSTALLATION AND PREPARATION FOR USE
THIS COOKER MUST BE HARDWIRED ONLY
Figure 2
3.3 ELECTRIC CONNECTION AND SAFETY
One-phase, 32A
Three-phase, 16A
Downloaded from www.vandenborre.be