PHYRO3000D
10
The easiest way is to start from the highest possible place value and to add the smaller values until the
start address will result.
The address is set to start as a binary number by means of DIP-switch No 1 - 9. Thus, it appears the addition
values of DIP-switches positioned to ON.
Examples with the start addresses 1, 6 and 104:
1
2
4
8
16
32
64
128
256
1
2
4
8
16
32
64
128
256
Switch number
Start address 1: switch No. 1 set to ON
Start address 6: switches No. 2 and 3 set to ON
Start address 104: switches Nos. 7, 6 and 4
set to ON
Place value
1
2
4
8
16
32
64
128
256
Summary of Contents for Tribe PHYRO3000D
Page 1: ...MANUALE UTENTE USER MANUAL PHYRO3000D IT EN FOG MACHINE ...
Page 15: ......
Page 31: ......