
13
PIXIEWASHXB
the
Studio
mode it is possible to use separately the 4 single colors, only when all the colors are full
you will get the color temperature of 6000 K.
-
White Balance
- White Balance function. Select the
White Balance
function to set the white balance by
changing the values (
125-255
) of the colors
Red, Green, Blue and White
.
-
Calibrated -
With this function active, when the RGB colors are full, you will get 6000 K. In the same
way, using only the Warm White channel, you will still get 6000 K. So this mean that with this func-
tion activated white of PIXIEWASHXB is not warm white but a standard cold white at 6000K.
NOTE: to obtain 3000 K using the Warm White color, you must necessarily disable the Calibrated function
and activate the Studio function.
-
Dimmer Mode
- Adjusting the dimmer. Enter in
Dimmer Mode
to select specific dimming curve.
Particularly when set:
•
Off:
The increase in light intensity is linear.
•
Dimmer 1:
dimmer curve with low fade.
•
Dimmer 2:
dimmer curve with medium fade.
•
Dimmer 3:
dimmer curve with high fade.
-
Dimmer selection -
Its function is to change the behavior of the Dimmer. Select the desired option
(
Option 1 / Option 2 / Option 3
).
-
Fan Mode
- Fan speed. Select the desired fan speed (
Off, Auto, Silent, High)
through the button UP/
DOWN.
-
Temperature unit
. Select
Temperature unit
function and then choose
Celsius / Fahrenheit
measurement unit
then press the RIGHT button to confirm the selection.
• Press repeatedly the button LEFT to return the menu mode.
3.11 AUTO TEST
Allow checking the proper functioning of the unit. Start the automatic test in the following way:
• Press the button LEFT to enter the menu mode.
• Use the buttons UP/DOWN to select the
Fixture
. Press the button RIGHT to confirm.
• Press the buttons UP/DOWN to select the
Auto Test
and press RIGHT to confirm.
• To confirm and start the automatic test press the RIGHT button.
3.12 MANUAL TEST
It allows to do adjustments on the effects through commands panel to obtain a perfect balance between
the projectors.
• Press the button LEFT to enter the menu mode.
• Press the buttons UP/DOWN to select the item
Fixture
. Then press the button RIGHT.
• Press the buttons UP/DOWN to select the
Manual Test
. Then press the button RIGHT.
• Select the effect you want change (
Pan, Pan Fine, Tilt, Tilt Fine, P/T Speed, Dimmer, Shutter, Red, Green, Blue, White,
Zoom)
.Then press the button RIGHT to confirm.
• Use the directional buttons to calibrate the effect setting a value between
0 - 255
. Then press the button
RIGHT to confirm.
• Press repeatedly the button LEFT to return the menu mode.
3.13 ADVANCED
It is possible to modify the following parameters following the same procedure:
• Press the LEFT button to access the main menu.
• Press the UP/DOWN button to scroll through the menu, select
Advanced
, then press the RIGHT button
to enter the next menu.
Summary of Contents for PIXIEWASHXB
Page 1: ...USER MANUAL MANUALE UTENTE PIXIEWASHXB WASH MOVING HEAD EN IT...
Page 46: ......
Page 47: ......