11
PIXIESPOT
Several units may be interconnected; follow the instructions below:
1. Connect the DMX OUT of the master unit via 3-pole XLR cable to the DMX IN of the first slave unit.
2. Connect the DMX OUT of the first slave unit to the DMX IN of the second slave unit, etc. until all units
are connected in a chain.
Use standard DMX cables to daisy chain your units together via the DMX connector on the rear of the
units. For longer cable runs we suggest a terminator at the last fixture (see page 13).
3.4 DMX ADDRESSING
To set DMX addressing follow the instructions below:
• Press the button LEFT to enter the menu mode.
• Use the buttons UP/DOWN to select the
DMX Functions
item. Press the button ENTER to confirm.
• Press the buttons UP/DOWN to select the
DMX Address
item. Then press the button ENTER to confirm.
• Press the buttons UP/DOWN to select the desired value
001-512
; Then press the button ENTER to con-
firm.
• Press repeatedly the button LEFT to return the menu mode.
To able to operate the PIXIESPOT with a light controller, adjust the DMX start address for the first a
DMX channel. If e. g. address 33 on the controller is provided for controlling the function of the first DMX
channel, adjust the start address 33 on the PIXIESPOT. The other functions of the light effect panel are then
automatically assigned to the following addresses.
Fig.5 - Example 15 DMX channels configuration
. . . . . . . . . . . .
DMX512 Controller
DMX Address: 78
DMX Address: 48
DMX Address: 33
DMX Address: 63
Number of
DMX channels
Start address
(example)
DMX Address
occupied
Next possible start
address for unit No. 1
Next possible start
address for unit No. 2
Next possible start
address for unit No. 3
15
33
33-47
48
63
78
18
33
33-50
51
69
87
23
33
33-55
56
79
102