background image

M200LED

12

3.12 Remote control EC800 (optional)

The remote control EC800 (fig. 2) available as an accessory allows to control different functions.

1.  Connect the remote control to the jack ONLY FOR REMOTE CONTROL (10).

2.  No DMX signal must be present at the DMX INPUT (11). The LED MASTER (5) must light up.

3.  Via the DMX OUTPUT (12), it is possible to connect further units in order to control them via the remote 

control together with the master unit.

4.  With  the  button  STAND  BY  (15),  the  sleep  mode  can  be  switched  on  and  off. With  the  sleep  mode 

switched on, the LED next to the button will light up. The pan head will go to its starting position and the 

light beam will be switched off.

5.  With the button MODE (17), select the operating mode:

a) SOUND mode (LED next to the button MODE does not light up).

Each time the button FUNCTION (16) is kept pressed, the unit changes to the next of the three strobo

-

scopic effects:

- Stroboscope independent of the music, in sync with the slave units;

- Stroboscope independent of the music, alternating with the slave units;

- Stroboscope depending on the music.

b) SHOW mode (LED flashing).

Select the desired show programme (Show 1 to 4) with the button FUNCTION (16).

c) How to choose color and gobo (LED lights continuosly).

- Press to select color;

- Hold to select gobo.

Note. The length of the cable remote EC800 is 10 m.

- 4 -  MAINTENANCE

4.1 Cleaning the unit and maintenance

•  Make sure the area below the installation place is free from unwanted persons during set-up.

•  Switch off the unit, unplug the main cable and wait until the unit has cooled down.

•  All screws used for installing the device and any of its parts should be tightly fastened and should not 

be corroded.

•  Housings, fixations and installation spots (ceiling, trusses, suspensions) should be totally free from any 

deformation.

•  When the lens is visibly damaged due to cracks or deep scratches, it must be replaced.

•  The main cables must be in impeccable condition and should be replaced immediately even when a 

small problem is detected.

•  In order to protect the device from overheating the cooling fans (if any), and ventilation openings should 

be cleaned monthly.

•  The interior of the device should be cleaned annually using a vacuum cleaner or air-jet.

•  It is recommended to clean the plastic panel of the unit at regular intervals, from impurities caused by 

dust, smoke, or other particles to ensure that the light is radiated at maximum brightness. For cleaning, 

disconnect the main plug from the socket. Use a soft, clean cloth moistened with a mild detergent. Then 

carefully wipe the plastic pane dry. For cleaning other housing parts use only a soft, clean cloth. Never 

use a liquid, it might penetrate the unit and cause damage to it.

Warning: we strongly recommend internal cleaning to be carried out by qualified personnel!

Summary of Contents for M200LED

Page 1: ...I GB Manuale Utente User Manual M200LED MOVING HEAD...

Page 2: ...REV 009 06 10...

Page 3: ...oni base 3 3 Funzionamento in modalit automatica 3 4 Impostazione della messa a fuoco 3 5 Comando tramite la musica 3 6 Selezione del programma Show 3 7 Collegamento 3 8 Collegamenti della linea DMX 3...

Page 4: ...possa provocare ustioni attendere almeno 30 minuti dallo spegnimento assolutamente necessario proteggere l unit per mezzo di una fune di sicurezza Nell eseguire qualsiasi intervento attenersi scrupolo...

Page 5: ...ndoEC800 fig 2 11 DMXIN XLRa3poli 1 massa 2 DMX 3 DMX 12 DMXOUT XLRa3poli 1 massa 2 DMX 3 DMX 13 Microfono per il comando tramite musica 14 Regolatore SENSITIVITY per la sensibilit in caso di comando...

Page 6: ...mmer lineare 0 100 Strobo Shutter effetto strobo ed effetti di dissolvenza con velocit regolabile Apertura e blackout istan tanei Ruota colore 8 colori dicroici open Effetto rainbow Ruota gobos rotant...

Page 7: ...ontata anche a testa in gi su una traversa Per il fissaggio occorrono dei supporti robusti per il montaggio Fissare i supporti alle staffe di montaggio 19 in dotazione i cui perni 20 come si vede nell...

Page 8: ...esiderata Quindi premere il tasto ENTER 4 Non far passare pi di 8 secondi fra due pressioni dei tasti per evitare di terminare la procedura d impostazione Impostazione dell indirizzo di start Addr 1 5...

Page 9: ...edente di funzionamento Permette di visualizzare la versione del firmware sistema operativo dell unit Contaore Fixture Hours Dopo aver premuto il tasto ENTER il display indica le ore di funzionamento...

Page 10: ...zare premere il tato ENTER Viene visualizzato nuovamente il numero del programma Show impostato e il programma inizia a svolgersi Per il comando tramite la musica impostare il regolatore SENSITIVITY 1...

Page 11: ...TPUT 12 dell unit principale con l ingresso DMX INPUT 11 della prima unit secondaria servendosi di un cavo XLR a 3 poli 2 Collegare l uscita DMX OUTPUT della prima unit secondaria con l ingresso DMX I...

Page 12: ...to ENTER 4 L indirizzo impostato viene indicato Con il tasto DOWN o UP 3 impostare l indirizzo e memorizzare con il tasto ENTER 2 Per uscire dal men tenere premuto il tasto MENU finch il display ritor...

Page 13: ...gobo shaking Gobo 1 shaking Gobo 2 shaking Gobo 3 shaking Gobo 4 shaking Gobo 5 shaking Gobo 6 shaking Rotation slow Rotation fast 000 009 010 018 019 027 028 036 037 046 047 055 056 063 064 127 064...

Page 14: ...cavo del telecomando pari a 10 m 4 MANUTENZIONE 4 1 Pulizia sistema ottico e manutenzione Durante gli interventi assicurarsi che l area sotto il luogo di installazione sia libera da personale non qual...

Page 15: ......

Page 16: ......

Page 17: ...settings 3 1 Operation 3 2 Basic adjustments 3 3 Operation without DMX controller 3 4 Focus setting 3 5 Music control 3 6 Selecting the Show programme 3 7 Linking 3 8 Connection of the DMX line 3 9 Co...

Page 18: ...er look directly at the light beam Before starting any maintenance work or cleaning of the unit cut off power from the main supply Make certain that the fixture is off and the temperature of the compo...

Page 19: ...tivity of re sponse in case of music control via the internal microphone 14 Microphone for music control 15 Remote control EC800 not included 16 STAND BY button for the sleep mode The pan head goes to...

Page 20: ...l through 3 poles XLR connection 7 channels at 16 bit Dimmer 0 100 linear dimming Strobe Shutter strobe and fading effects with adjustable speed Instant open and blackout Colour wheel 6 dichroic color...

Page 21: ...plate is shown in figure 3 For fixing stable mounting clips are required Directly screw the clips into the M6 threads or fasten them to the sup plied mounting brackets 19 As shown in the figure place...

Page 22: ...s shown in the display 1 Then press the button ENTER 4 Never wait for more than 8 seconds to press the next button otherwise the adjusting procedure will be stopped 3 FUNCTIONS AND SETTINGS Adjustment...

Page 23: ...nu item will flash for 8 seconds Then the menu will disappear To display the version number of the firmware operating system of the light effect unit Working hour meter fixture hours After pressing th...

Page 24: ...with the DOWN or UP button 3 4 To memorize press the button ENTER The number of the adjusted show programme reappears and the programme run is started For music control adjust the control SENSITIVITY...

Page 25: ...units may be interconnected in order to control all further slave units to the same rhythm via the microphone of the master unit Connect the DMX OUTPUT 12 of the master unit via a 3 pole XLR cable to...

Page 26: ...for this example 1 Adjusting the DMX start address Press the MENU button 2 once so that the display 1 will show Addr Never wait for more than 8 seconds to press the next button otherwise the adjustin...

Page 27: ...shaking Gobo 1 shaking Gobo 2 shaking Gobo 3 shaking Gobo 4 shaking Gobo 5 shaking Gobo 6 shaking Rotation slow Rotation fast 000 009 010 018 019 027 028 036 037 046 047 055 056 063 064 127 064 073 0...

Page 28: ...of the cable remote EC800 is 10 m 4 MAINTENANCE 4 1 Cleaning the unit and maintenance Make sure the area below the installation place is free from unwanted persons during set up Switch off the unit un...

Page 29: ......

Page 30: ......

Page 31: ...conseguenti sono a carico del possessore dell apparecchio A tutti gli effetti la validit della garanzia avallata unicamente dalla presentazione del certificato di garanzia The guarantee covers the un...

Page 32: ...ate Data acquisto FORM TO BE FILLED IN AND MAILED CEDOLA DA COMPILARE E SPEDIRE FORM TO BE FILLED IN AND KEPT CEDOLA DA COMPILARE E CONSERVARE PROV ZIP CODE C A P MODEL MODELLO SERIAL N SERIE N Purcha...

Page 33: ......

Page 34: ......

Page 35: ......

Page 36: ...usic Lights S r l PROLIGHTS is a brand of Music Lights S r l company Via Appia Km 136 200 04020 Itri LT ITALY tel 39 0771 72190 fax 39 0771 721955 www musiclights it info musiclights it Music Lights S...

Reviews: