background image

LUMIPAR18VWPRO

8

3.3 MENU STRUCTURE

MENU (LEVEL 1)

(LEVEL 2)

(LEVEL 3)

REMARK

1

Auto

Auto

Speed

< Auto 1 >

< Auto 1 >

< 100 >

< Auto 2 >

< 100 >

< Auto 3 >

< 100 >

< Auto 4 >

< 100 >

< Auto 5 >

< 100 >

2

Static

Static

Fix C

 

< Fix C >

<    W >

< C      >
< C W >

< Manu C > Manual C

Value

< W=255>

< W=255>

< C=255 >

< C=255 >

3

Dim Mode

Dim Mode

< DIM 1 >

<    Off    >

Default: On

< DIM 1 >

DIM 1: Dimmer speed fast 0.8 s

< DIM 2 >

DIM 2: Dimmer speed middle 1.6 s

< DIM 3 >

DIM 3: Dimmer speed slow 2.4 s

4

Back Lite

Back Lite

< On >

<  On   >

Default: On

< 10 s >

10 s: Off after 10 seconds

< 20 s >

20 s: Off after 20 seconds

< 30 s >

30 s: Off after 30 seconds

5

Info

Auto

Auto

 

Test

Test

Fix Hours

Fixture running time 0-9999H

< 0 H >

Default: 0H

Version

< V1.0 >

6

Address

Address

DMX address(001-512) Default: 001

< 001 >

< 512 >

2 Ch: (001-511)
3 Ch: (001-510)
7 Ch: (001-506)

7

Channel

Channel

DMX Channel

< 2Ch >

< 2Ch >

Default: 7Ch

< 3Ch >
< 7Ch >

Summary of Contents for LUMIPAR18VWPRO

Page 1: ...EN IT Manuale Utente User Manual LUMIPAR18VWPRO SUPER SLIM LED PAR ...

Page 2: ...rziale per propri scopi commerciali è vietata Al fine di migliorare la qualità dei prodotti la Music Lights S r l si riserva la facoltà di modificare in qualunque momento e senza preavviso le specifiche menzionate nel presente manuale di istruzioni Tutte le revisioni e gli aggiornamenti sono disponibili nella sezione Manuali sul sito www musiclights it ...

Page 3: ... 1 Funzionamento 3 2 Impostazione base 3 3 Struttura menu 3 4 Modalità Auto Show 3 5 Modalità Static 3 6 Modalità Master Slave 3 7 Collegamento 3 8 Configurazione canale DMX 3 9 Modalità DMX 3 10 Collegamenti della linea DMX 3 11 Costruzione del terminatore DMX 3 12 Tabella canali DMX 3 13 Funzioni dispositivo 3 14 Informazioni sul dispositivo 3 15 Calibrazione bianco 4 Manutenzione 4 1 Manutenzio...

Page 4: ...e ai 45 C Evitare che nell unità penetrino liquidi infiammabili acqua o oggetti metallici Non smontare e non apportare modifiche all unità Tutti gli interventi devono essere sempre e solo effettuati da personale tecnico qualificato Rivolgersi al più vicino centro di assistenza tecnica autorizzato Se si desidera eliminare il dispositivo definitivamente consegnarlo per lo smaltimento ad un istituzio...

Page 5: ...e delle Condizioni Generali di Garanzia Si prega dopo l acquisto di procedere alla registrazione del prodotto sul sito www musiclights it In alternativa il prodotto può essere registrato compilando e inviando il modulo riportato alla fine del manuale A tutti gli effetti la validità della garanzia è avallata unicamente dalla presentazione del certificato di garanzia Music Lights constata tramite ve...

Page 6: ...onica Pannello di controllo tramite display LCD 4 caratteri Diverse configurazioni DMX disponibili 2 3 e 7 canali per controllo professionale o semplificato 2 canali WW CW 3 canali Dimmer WW CW 7 canali Dimmer WW CW Shutter Auto Programs Auto Program speed curva dimmer Modalità Automatica 5 programmi automatici preimpostati con regolazione velocità Modalità colori statici riproduzione statica dei ...

Page 7: ... terra del dispositivo 7 ALLOGGIAMENTO FUSIBILE in caso di rottura del fusibile sostituire sempre con uno dello stesso tipo e dello stesso valore 8 POWER IN connettore di potenza Neutrik per il collegamento ad una presa di rete 100 240V 50 60Hz tramite il cavo rete in dotazione 9 POWER OUT connettore di potenza Neutrik output alimentazione per connessione di più unità in serie 10 SAFETY EYE per l ...

Page 8: ...ilità sufficiente e supportare almeno 10 volte il peso dell unità Inoltre assicurarsi di rispettare tutte le avvertenze in materia di sicurezza Fissare il proiettore attraverso l apposita staffa 1 ad una collocazione idonea È assolutamente necessario assicurare il proiettore contro la caduta utilizzando un cavo di sicurezza in particolare collegare il cavo in un punto adatto in modo che la caduta ...

Page 9: ...ta da un interruttore 3 2 IMPOSTAZIONE BASE Il proiettore LUMIPAR18VWPRO dispone di un LED display e 4 pulsanti per accesso alle funzioni del pan nello di controllo fig 4 Fig 4 MENU ENTER UP DOWN Per scorrere il menu principale o tornare ad una opzione del menu precedente Per entrare nel menu selezionato o confermare il valore attuale della funzione o l opzione all interno di un menu Per scorrere ...

Page 10: ...IM 1 Dimmer speed fast 0 8 s DIM 2 DIM 2 Dimmer speed middle 1 6 s DIM 3 DIM 3 Dimmer speed slow 2 4 s 4 Back Lite Back Lite On On Default On 10 s 10 s Off after 10 seconds 20 s 20 s Off after 20 seconds 30 s 30 s Off after 30 seconds 5 Info Auto Auto Test Test Fix Hours Fixture running time 0 9999H 0 H Default 0H Version V1 0 6 Address Address DMX address 001 512 Default 001 001 512 2 Ch 001 511 ...

Page 11: ...l tasto ENTER Impostare i valori 000 255 attraverso i tasti UP DOWN quindi premere il tasto ENTER PremereiltastoMENUpertornareindietrooattenderealcunisecondiperusciredalmenudiimpostazione 3 5 MODALITÀ STATIC L unità dispone di preset colori pre programmati W C CW che possono essere impostati attraverso la se guente procedura Per entrare nella modalità static premere il tasto MENU ripetutamente fin...

Page 12: ...i contatti XLR a 3 poli 3 9 MODALITÀ DMX Per impostare l indirizzo DMX premere il tasto MENU fino a quando sul display non appare ADDRESS quindi premere il tasto ENTER Premere il tasto UP DOWN per selezionare il valore desiderato 001 512 tenere premuto invece il tasto UP DOWN per lo scorrimento veloce Premere il tasto ENTER per confermare l impostazione Per poter comandare il LUMIPAR18VWPRO con un...

Page 13: ... Collegare quindi l uscita DMX con l ingresso DMX della successiva unità l uscita di quest ultima con l ingresso di quella successiva e via dicendo finchè tutte le unità sono collegate formando una catena Per installazioni in cui il cavo di segnale deve percorrere lunghe distanze è consigliato inserire sull ulti ma unità una terminazione DMX 3 11 COSTRUZIONE DEL TERMINATORE DMX La terminazione evi...

Page 14: ...00 051 052 101 102 152 153 203 204 254 255 255 6 AUTO PROGRAM SPEED Only when CH7 is between 052 255 0 100 slow fast 000 255 7 DIMMER SPEED Default dimmer speed Linear dimmer Non linear dimmer 1 Non linear dimmer 2 Non linear dimmer 3 000 051 052 101 102 152 153 203 204 255 CH Function in CH2 mode Value 1 WARMWHITE 0 100 000 255 2 COOLWHITE 0 100 000 255 CH2 CH Function in CH3 mode Value 1 MASTER ...

Page 15: ...te di verificare il corretto funzionamento dell unità Per avviare il test procedere nel seguente modo Premere il tasto MENU ripetutamente fino a quando sul display non compare INFO quindi premere ENTER per confermare Selezionare attraverso i tasti UP DOWN la funzione AUTOTEST Per confermare e dare l avvio al test automatico premere il tasto ENTER FixHours Permette di visualizzare le ore di funzion...

Page 16: ...o a quando sul display non appare WHITE BALANCE quindi premere il tasto ENTER Selezionare il canale WarmWhite W e il ColdWhite C attraverso i tasti UP DOWN Per confermare premere il tasto ENTER Impostare i valori 000 255 attraverso i tasti UP DOWN quindi premere il tasto ENTER PremereiltastoMENUpertornareindietrooattenderealcunisecondiperusciredalmenudiimpostazione ...

Page 17: ...iavite rimuovere il portafusibile dalla sua sede e il fusibile bruciato dal suo supporto sostituire il fusibile con uno identico per tipologia e valore 3 Inserire il portafusibile al suo posto e ricollegare l alimentazione 4 3 RISOLUZIONE DEI PROBLEMI Fig 8 Anomalie Possibili cause Controlli e rimedi Il proiettore non illumina Mancanza di alimentazione di rete Dimmer impostato a 0 Tutti i colori i...

Page 18: ...r by any means for any commercial use In order to improve the quality of products Music Lights S r l reserves the right to modify the characteristics stated in this instruction manual at any time and without prior notice All revisions and updates are available in the manuals section on site www musiclights it ...

Page 19: ... 2 1 Mounting 3 Functions and settings 3 1 Operation 3 2 Basic 3 3 Menu structure 3 4 Auto Show mode 3 5 Static mode 3 6 Master Slave mode 3 7 Linking 3 8 DMX configuration 3 9 DMX mode 3 10 Connection of the DMX line 3 11 Construction of the DMX termination 3 12 DMX control 3 13 Fixture settings 3 14 Fixure information 3 15 White calibration 4 Maintenance 4 1 Maintenance and cleaning the unit 4 2...

Page 20: ...le liquids water or metal objects enter the fixture Do not dismantle or modify the fixture All work must always be carried out by qualified technical personnel Contact the nearest sales point for an inspection or contact the manufacturer directly If the unit is to be put out of operation definitively take it to a local recycling plant for a disposal which is not harmful to the environment Warnings...

Page 21: ...site www musiclights it Please remember to register the piece of equipment soon after you purchase it logging on www musiclights it The product can be also registered filling in and sending the form available on your guarantee certificate For all purposes the va lidity of the guarantee is endorsed solely on presentation of the guarantee certificate Music Lights will verify the validity of the clai...

Page 22: ...MX selectable configurations 2 3 7 channels for advanced or basic control 2 channels WW CW 3 channels Dimmer WW CW 7 channels Dimmer WW CW Strobe Auto Program Auto Program speed dimmer curve Auto mode 5 built in programs with execution speed adjustment Static colour mode selection of static colour Master Slave mode for synchronized operation of more units linked in a chain Linear and stepless tran...

Page 23: ...nage them 6 GND POINT grounding the fixture to the earth 7 FUSE OLDER in the event of breakage always replace the fuse with the same type and rating 8 POWER IN Neutrik connector for connection to a socket 100 240V 50 60Hz via the supplied mains cable 9 POWER OUT Neutrik connector power output for connection of multiple units in series 10 SAFETY EYE to attach safety cable SAFETY ROPE DMX OUT DMX IN...

Page 24: ...ys comply scrupulously with all the regulations particularly re garding safety currently in force in the country in which the fixture s being used Install the projector at a suitable location by means of the mounting bracket 1 Always additionally secure the projector with the safety rope from falling down For this purpose fas ten the safety rope at a suitable position so that the maximum fall of t...

Page 25: ... unit to a socket which can be switched on and off via a light switch 3 2 BASIC Access control panel functions using the four panel buttons located directly underneath the LCD Display fig 4 MENU ENTER UP DOWN Used to access the menu or to return a previous menu option Used to select and store the current menu or confirm the current function value or option within a menu Navigates downwards through...

Page 26: ...IM 1 Dimmer speed fast 0 8 s DIM 2 DIM 2 Dimmer speed middle 1 6 s DIM 3 DIM 3 Dimmer speed slow 2 4 s 4 Back Lite Back Lite On On Default On 10 s 10 s Off after 10 seconds 20 s 20 s Off after 20 seconds 30 s 30 s Off after 30 seconds 5 Info Auto Auto Test Test Fix Hours Fixture running time 0 9999H 0 H Default 0H Version V1 0 6 Address Address DMX address 001 512 Default 001 001 512 2 Ch 001 511 ...

Page 27: ...h the buttons UP DOWN Press the button ENTER to confirm Set the value 000 255 through the buttons UP DOWN Press the MENU button to go back or to meet the waiting time to exit the setup menu 3 5 STATIC MODE The fixture has preprogrammed static looks that may be triggered without a controller W C CW Access these chases via the control panel on the back of the fixture To enable the static mode press ...

Page 28: ...lay shows ADDRESS and press the button ENTER to confirm Press UP DOWN button to select the desired value 001 512 Press and hold to scroll quickly Press ENTER button to store Press the MENU button to go back or to meet the waiting time to exit the setup menu To able to operate the LUMIPAR18VWPRO with a light controller adjust the DMX start address for the first a DMX channel If e g address 33 on th...

Page 29: ...of the first unit Connect the DMX output to the DMX input of the following unit Connect again the output to the input of the following unit until all the units are connected in chain When the signal cable has to run longer distance is recommended to insert a DMX termination on the last unit DMX OUTPUT XLR socket DMX INPUT XLR plug Pin1 GND Shield Pin2 Negative Pin3 Positive Fig 6 3 11 CONSTRUCTION...

Page 30: ...051 052 101 102 152 153 203 204 254 255 255 6 AUTO PROGRAM SPEED Only when CH7 is between 052 255 0 100 slow fast 000 255 7 DIMMER SPEED Default dimmer speed Linear dimmer Non linear dimmer 1 Non linear dimmer 2 Non linear dimmer 3 000 051 052 101 102 152 153 203 204 255 CH Function in CH2 mode Value 1 WARMWHITE 0 100 000 255 2 COOLWHITE 0 100 000 255 CH2 CH Function in CH3 mode Value 1 MASTER DIM...

Page 31: ... 14 FIXTURE INFORMATION Auto Test Allow checking the proper functioning of the unit Start the automatic test in the following way Press the button MENU so many times until shows INFO then press the ENTER button to confirm Using the button UP DOWN to select AUTOTEST To confirm and start the automatic test press the ENTER button FixHours Show the fixture working hours Press the button MENU so many t...

Page 32: ...ton MENU so many times until shows WHITE BALANCE and press the button ENTER to con firm Select WarmWhite W e il ColdWhite through the buttons UP DOWN Press MENU button to confirm Set the value 000 255 through the buttons UP DOWN Press the MENU button to go back or to meet the waiting time to exit from the setup menu automati cally ...

Page 33: ... penetrate the unit and cause damage to it 4 2 FUSE REPLACEMENT 1 Remove the safety cap by a screwdriver 2 Replace the blown fuse with a fuse of the exact same type and rating 3 Install the safety cap and reconnect power 4 3 TROUBLESHOOTING Fig 8 Problems Possible causes Checks and remedies Fixture does not light up No mains supply Dimmer fader set to 0 All color faders set to 0 Faulty LED Faulty ...

Page 34: ......

Page 35: ...chi conseguenti sono a carico del possessore dell apparecchio A tutti gli effetti la validità della garanzia è avallata unicamente dalla presentazione del certificato di garanzia The guarantee covers the unit in compliance with existing regulations You can find the full version of the General Guarantee Conditions on our web site www musiclights it Abstract General Guarantee Conditions Please remem...

Page 36: ...date Data acquisto FORM TO BE FILLED IN AND MAILED CEDOLA DA COMPILARE E SPEDIRE FORM TO BE FILLED IN AND KEPT CEDOLA DA COMPILARE E CONSERVARE PROV ZIP CODE C A P MODEL MODELLO SERIAL N SERIE N Purchased by Acquistato da SURNAME COGNOME Dealer s stamp and signature Timbro e firma del Rivenditore NAME NOME ADDRESS VIA N CITY CITTà Purchasing date Data acquisto PROV ZIP CODE C A P ...

Page 37: ......

Page 38: ......

Page 39: ......

Page 40: ...39 0771 721955 www musiclights it info musiclights it Music Lights S r l entertainment technologies ISO 9001 2008 Certified Company 2013 Music Lights S r l PROLIGHTS è un brand di proprietà della Music Lights S r l PROLIGHTS is a brand of Music Lights S r l company ...

Reviews: