Problems

Possible causes

Checks and remedies

Product doesn’t power ON •  No power to the 

product.

•  Check that power is switched ON and cables are 

plugged in.

•  Fuse blown or internal 

fault.

•  Check if the Fuse is intact and eventually replace it if 

necessary.

• 

Contact the PROLIGHTS Service or authorized service 

partner. Do not remove parts and/or covers, or carry 

out any repairs or service that are not described in 

this  Safety  and  User  Manual  unless  you  have  both 

authorization  from  PROLIGHTS  and  the  service 

documentation.

Product reset correctly but 

does not respond correctly 

to the contoller.

• 

Bad signal connection.

•  Inspect connections and cables. Fix eventual bad 

connections. Repair or replace damaged cables.

•  Signal connection not 

terminated.

• 

Insert DMX termination plug in signal output socket of 

the last product on the signal line.

•  Incorrect addressing of 

the product.

•  Check the product address and control settings.

•  One of the product is 

defective and is corrupt

-

ing the signal transmis

-

sion on the signal line.

• 

Unplug  the  XLR  in  and  out  connectors  and  connect 

them directly together to bypass one product at a 

time until normal operation is regained. Once found 

the  error,  have  that  fixture  serviced  by  a  qualified 

technician.

Timeout error after fixture 

reset.

•  One or more hardware 

components requires 

mechanical adjustments.

•  Check product stored error messages for more 

information. Contact PROLIGHTS Service or an 

authorized service partner.

Mechanical effect loses 

position

• 

Mechanical 

hardware 

require cleaning, adjust

-

ment or lubrification

•  Check product stored error messages for more 

information. Contact PROLIGHTS Service or an 

authorized service partner.

Light output turn OFF 

Intermittently

•  Fixture is too hot

•  Check product stored error messages.

•  Allow product to cool.

• 

Clean the product and airflow filters.

•  Reduce ambient temperature.

•  Hardware failure (tem

-

perature sensor, fans, 

Light source...).

•  Check product stored error messages for more 

information. Contact. PROLIGHTS Service or an 

authorized service partner.

General low light intensity

•  Dirty lens assembly.

• 

Dirty or damaged filters.

• 

Clean the fixture regularly.

•  Install lens assembly properly.

Contact an authorized service center in case of technical problems or not reported in the table can not 

be resolved by the procedure given in the table.

TROUBLESHOOTING

Summary of Contents for EclFresnel PTW

Page 1: ...USER MANUAL REV 02 05 21 English version EclFresnel TW EclFresnel PTW LED Fresnel FC and Tunable White with colour correction to replace 1 000W lamp...

Page 2: ...onomic loss or any other loss occasioned by the use of inability to use or reliance on the information contained in this document Product user manual can be downloaded from the website www prolights i...

Page 3: ...11 INSTRUCTIONS FOR A RELIABLE DMX CONNECTION 11 CONNECTION DAISY CHAIN 11 CONNECTION OF THE DMX LINE 11 CONSTRUCTION OF THE DMX TERMINATION 12 DMX ADDRESSING 12 8 CONTROL PANEL 13 DISPLAY AND BUTTONS...

Page 4: ...les are in perfect condition and rated for the current requirements of all connected devices Isolate the fixture from power immediately if the power plug or any seal cover ca ble or other components a...

Page 5: ...ill damage the fixture Damages caused by inadequate cleaning or maintenance are not covered by the product warranty T 60 C c Temperature of the external surface The surface of the fixture can reach up...

Page 6: ...To preserve the environment please dispose recycle this product at the end of its life according to the local regulation The products to which this manual refers comply with 2014 35 EU Safety of elec...

Page 7: ...L 3m 958225L03 3x2 5mm TH07 Cable 16A 3p PwCon MXW 16A 3p PwCon FXW L 3m 9513FXWL03 ass 3x2 5mm TH07 cable 16A 3p 230V CEE plug MENAC3FXW socket L 5 m 9533FXWL03 ass 3x2 5mm TH07 cable SCHUKO plug ME...

Page 8: ...mm 17 3 in 100 mm 3 9 in 539 mm 21 2 in 343 mm 13 5 in 283 mm 11 2 in 100 mm 3 9 in 435 mm 17 1 in 535 mm 21 1 in 342 mm 13 4 in 558 mm 21 9 in 343 mm 13 5 in 285 mm 11 2 in 552 mm 21 7 in Fig 01 ECLF...

Page 9: ...539 mm 21 2 in 100 mm 3 9 in 439 mm 17 3 in 283 mm 11 2 in 100 mm 3 9 in 535 mm 21 1 in 635 mm 25 0 in 443 mm 17 4 in 652 mm 25 7 in 546 mm 21 5 in 286 mm 11 2 in Fig 02 ECLFRESNELPTW Weight 9 7 kg 2...

Page 10: ...is approved as a safety attachment for the weight of the fixture to an anchor point on the product main frame Do not use removable parts or weak anchors for secondary attachment Warning When clamping...

Page 11: ...ower from the product disconnect the Mains from the socket 4 CONNECTION TO THE MAINS SUPPLY WARNING For protection from electric shock the fixture must be earthed The product is equipped with auto swi...

Page 12: ...OB zoom function 7 WHITE KNOB tilt function 8 BLUE KNOB pan function 9 MAIN FUSE HOLDER replace a burnt out fuse by one of the same type only T3 15A 250V 10 POWER IN for connection to the Mains 100 24...

Page 13: ...he connection line Do not overload the link Up to 32 devices may be connected on a serial link CONNECTION DAISY CHAIN Connect the DMX data output from the DMX source to the product DMX input male conn...

Page 14: ...be executing the same behaviour Selecting the same address to multiple fixtures can be useful for diagnostic purposes and symmetrical control DMX addressing is limited to make it impossible to set th...

Page 15: ...ons MENU used to access the menu tree or to return a previous menu window UP browse upwards through the menu list and increases the numeric value displayed DOWN browse downwards through the menu list...

Page 16: ...er 71 97 777 8CH 9CH 12CH 13CH 16CH 19CH 21CH 2 SETUP SCREEN BACKLIGHT ON Allows you to select the timing after that display will switch automatically off when unactive 10 s 20 s 30 s FLIP DISPLAY NO...

Page 17: ...you to link and oper ating in synk multiple units without a DMX console Choose a unit to perform as the Master This unit must be the first unit in line Set the successive units to be slave SLAVE EFFE...

Page 18: ...G RB L R G B L R RB B L O G RB B O G RB L O G B L O RB B L G RB B L R O G RB B R O G RB L R O G B L R O RB B L R G RB B L O G RB B L R O G RB B L DIMMER 000 255 COLOR PICKER 3200K 71 97 100 101 102 1...

Page 19: ...pecific fixtures The PIDs in the following tables are supported in the product CATEGORY PARAMETER PID GET SET Product Information DEVICE_INFO 0x0060 x DEVICE_MODEL_DESCRIPTION 0x0080 x MANUFACTURER_LA...

Page 20: ...DIMMER RED DIMMER COLOR PICKER 2 DIMMER SPEED MODE CTO DIMMER FINE ORANGE RED DIMMER 3 HUE CTO GREEN ORANGE RED 4 COLOR MACRO COLOR MACRO ROYAL BLUE GREEN ORANGE 5 DIMMER SPEED MODE DIMMER SPEED MODE...

Page 21: ...7 LIME BLUE ROYAL BLUE GREEN GREEN RED 8 STROBE LIME ROYAL BLUE FINE GREEN FINE GREEN FINE RED FINE 9 DIMMER SPEED MODE CTO BLUE ROYAL BLUE ROYAL BLUE ORANGE 10 HUE BLUE FINE ROYAL BLUE FINE ROYAL BLU...

Page 22: ...400K 5600K 5600K 5800K 5800K 6000K 6000K 6200K 6200K 6400K 6400K 6600K 6600K 6800K 6800K 7000K 7000K 7200K 7200K 7400K 7400K 7600K 7600K 7800K 7800K 8000K 8000K 8200K 8200K 8400K 8400K 8600K 8600K 880...

Page 23: ...4 ROYAL BLUE FINE 0 100 000 255 000 5 6 7 6 7 9 11 11 15 BLUE 0 100 000 255 000 10 12 12 16 BLUE FINE 0 100 000 255 000 6 7 8 7 8 11 13 13 17 LIME 0 100 000 255 000 12 14 14 18 LIME FINE 0 100 000 255...

Page 24: ...N FILTER FRAME CODE ECLFRSTPG OPTIONAL 2 3 DETAIL 1 Press the pin 1 and the snap will automatically open upwards 2 Insert the gel filter frame 3 into the gel frame lock DETAIL and close down the snap...

Page 25: ...3 2 DETAIL 1 1 Press the pin 1 and the snap will automatically open upwards 2 Insert the barn door 3 into the gel frame lock DETAIL 1 throught the holder assembly of the barn door DETAIL 2 Then close...

Page 26: ...NS CODE ECLFRSNL OPTIONAL 2 3 DETAIL 1 Press the pin 1 and the snap will automatically open upwards 2 Insert the narrow angle lens 3 into the gel frame lock DETAIL and close down the snap NOTE To remo...

Page 27: ...ed personnel It is PROLIGHTS policy to apply the strictest possible calibration procedures and use the best quality materials available to ensure optimum performance and the longest possible component...

Page 28: ...ectors and connect them directly together to bypass one product at a time until normal operation is regained Once found the error have that fixture serviced by a qualified technician Timeout error aft...

Page 29: ...Note...

Page 30: ...Note...

Page 31: ......

Page 32: ...PROLIGHTS is a trademark of MUSIC LIGHTS S r l musiclights it prolights it support prolights it Via A Olivetti snc 04026 Minturno LT ITALY Tel 39 0771 72190...

Reviews: