background image

PROLIGHTS - EclFresnel 

TW / PTW

25

13 - MAINTENANCE

MAINTENANCE AND CLEANING THE PRODUCT

WARNING: Disconnect from the mains before starting any maintenance work

It is recommended to clean the front at regular intervals, from impurities caused by dust, smoke, or 

other particles to ensure that the light is radiated at maximum brightness.

• 

For cleaning, disconnect the main plug from the socket. Use a soft, clean cloth moistened with a 

mild detergent. Then carefully wipe the part dry. For cleaning other housing parts use only a soft, 

clean cloth. Never use a liquid, it might penetrate the unit and cause damage to it.

•  The user must clean the product periodically to maintain optimum performance and cooling. The 

user may also upload firmware (product software) to the fixture via the DMX signal input port or USB 

port using firmware and instructions from PROLIGHTS.

•  The frequency of such maintenance operations is to be performed according to various factors, such 

as the amount of the use and the condition of the installation environment (air humidity, presence 

of dust, salinity, etc.). It is recommended that the product is subject to annual service by a qualified 

technician for special maintenance involving at least the following procedures:

•  General cleaning of internal parts.

• 

For all the parts subject to friction, using lubricants specifically supplied by PROLIGHTS.

•  General visual check of the internal components, cabling, mechanical parts, etc.

•  Electrical, photometric and functional checks; eventual repairs.

•  Cleaning the lenses. Only use neutral soap and water to clean the lenses, then dry it carefully with 

a soft, non-abrasive cloth.

WARNING: the use of alcohol or any other detergent could damage the lenses.

•  All other service operations on the product must be carried out by PROLIGHTS, its approved service 

agents or trained and qualified personnel.

•  It is PROLIGHTS policy to apply the strictest possible calibration procedures and use the best quality 

materials available to ensure optimum performance and the longest possible component lifetimes. 

However, optical components are subject to wear and tear over the life of the product, resulting 

in gradual changes in colours over many thousands of hours of use. The extent of wear and tear 

depends heavily on operating conditions and environment, so it is impossible to specify precisely 

whether and to what extent performance will be affected. However, you may eventually need to re

-

place optical components if their characteristics are affected by wear and tear after an extended pe

-

riod of use and if you require fixtures to perform within very precise optical and colour parameters.

• 

Do not apply filters, lenses or other materials on lenses or other optical components. Use only ac-

cessories approved by PROLIGHTS.

REPLACING THE FUSE

WARNING: Before replacing the fuse, unplug the product from the mains.

•  Remove the old fuse from the housing with a suitable screwdriver (anticlockwise) and replace it with 

one of the same type and of the same classification (T3.15A 250V).

VISUAL CHECK OF PRODUCT HOUSING

•  The parts of the product cover/housing should be checked for eventual damages and breaking 

start at least every two months. In addition, especially the parts of the front lens holder have to be 

checked mechanically (by means of movement by the part) if it is firmly fastened to the fixture. If 

hint of a crack is found on some plastic part, do not use the product until the damaged part will be 

replaced.

•  Cracks or another damages of the cover/housing parts can be caused by the product transportation 

or manipulation and also ageing process may influence materials.

• 

This checking is necessary for both fixed installations and preparing product for renting. Any free 

moving parts inside of the product, cracked cover/housing or any part of front lens not sitting prop

-

erly in place need to be immediately replaced.

Summary of Contents for EclFresnel PTW

Page 1: ...USER MANUAL REV 02 05 21 English version EclFresnel TW EclFresnel PTW LED Fresnel FC and Tunable White with colour correction to replace 1 000W lamp...

Page 2: ...onomic loss or any other loss occasioned by the use of inability to use or reliance on the information contained in this document Product user manual can be downloaded from the website www prolights i...

Page 3: ...11 INSTRUCTIONS FOR A RELIABLE DMX CONNECTION 11 CONNECTION DAISY CHAIN 11 CONNECTION OF THE DMX LINE 11 CONSTRUCTION OF THE DMX TERMINATION 12 DMX ADDRESSING 12 8 CONTROL PANEL 13 DISPLAY AND BUTTONS...

Page 4: ...les are in perfect condition and rated for the current requirements of all connected devices Isolate the fixture from power immediately if the power plug or any seal cover ca ble or other components a...

Page 5: ...ill damage the fixture Damages caused by inadequate cleaning or maintenance are not covered by the product warranty T 60 C c Temperature of the external surface The surface of the fixture can reach up...

Page 6: ...To preserve the environment please dispose recycle this product at the end of its life according to the local regulation The products to which this manual refers comply with 2014 35 EU Safety of elec...

Page 7: ...L 3m 958225L03 3x2 5mm TH07 Cable 16A 3p PwCon MXW 16A 3p PwCon FXW L 3m 9513FXWL03 ass 3x2 5mm TH07 cable 16A 3p 230V CEE plug MENAC3FXW socket L 5 m 9533FXWL03 ass 3x2 5mm TH07 cable SCHUKO plug ME...

Page 8: ...mm 17 3 in 100 mm 3 9 in 539 mm 21 2 in 343 mm 13 5 in 283 mm 11 2 in 100 mm 3 9 in 435 mm 17 1 in 535 mm 21 1 in 342 mm 13 4 in 558 mm 21 9 in 343 mm 13 5 in 285 mm 11 2 in 552 mm 21 7 in Fig 01 ECLF...

Page 9: ...539 mm 21 2 in 100 mm 3 9 in 439 mm 17 3 in 283 mm 11 2 in 100 mm 3 9 in 535 mm 21 1 in 635 mm 25 0 in 443 mm 17 4 in 652 mm 25 7 in 546 mm 21 5 in 286 mm 11 2 in Fig 02 ECLFRESNELPTW Weight 9 7 kg 2...

Page 10: ...is approved as a safety attachment for the weight of the fixture to an anchor point on the product main frame Do not use removable parts or weak anchors for secondary attachment Warning When clamping...

Page 11: ...ower from the product disconnect the Mains from the socket 4 CONNECTION TO THE MAINS SUPPLY WARNING For protection from electric shock the fixture must be earthed The product is equipped with auto swi...

Page 12: ...OB zoom function 7 WHITE KNOB tilt function 8 BLUE KNOB pan function 9 MAIN FUSE HOLDER replace a burnt out fuse by one of the same type only T3 15A 250V 10 POWER IN for connection to the Mains 100 24...

Page 13: ...he connection line Do not overload the link Up to 32 devices may be connected on a serial link CONNECTION DAISY CHAIN Connect the DMX data output from the DMX source to the product DMX input male conn...

Page 14: ...be executing the same behaviour Selecting the same address to multiple fixtures can be useful for diagnostic purposes and symmetrical control DMX addressing is limited to make it impossible to set th...

Page 15: ...ons MENU used to access the menu tree or to return a previous menu window UP browse upwards through the menu list and increases the numeric value displayed DOWN browse downwards through the menu list...

Page 16: ...er 71 97 777 8CH 9CH 12CH 13CH 16CH 19CH 21CH 2 SETUP SCREEN BACKLIGHT ON Allows you to select the timing after that display will switch automatically off when unactive 10 s 20 s 30 s FLIP DISPLAY NO...

Page 17: ...you to link and oper ating in synk multiple units without a DMX console Choose a unit to perform as the Master This unit must be the first unit in line Set the successive units to be slave SLAVE EFFE...

Page 18: ...G RB L R G B L R RB B L O G RB B O G RB L O G B L O RB B L G RB B L R O G RB B R O G RB L R O G B L R O RB B L R G RB B L O G RB B L R O G RB B L DIMMER 000 255 COLOR PICKER 3200K 71 97 100 101 102 1...

Page 19: ...pecific fixtures The PIDs in the following tables are supported in the product CATEGORY PARAMETER PID GET SET Product Information DEVICE_INFO 0x0060 x DEVICE_MODEL_DESCRIPTION 0x0080 x MANUFACTURER_LA...

Page 20: ...DIMMER RED DIMMER COLOR PICKER 2 DIMMER SPEED MODE CTO DIMMER FINE ORANGE RED DIMMER 3 HUE CTO GREEN ORANGE RED 4 COLOR MACRO COLOR MACRO ROYAL BLUE GREEN ORANGE 5 DIMMER SPEED MODE DIMMER SPEED MODE...

Page 21: ...7 LIME BLUE ROYAL BLUE GREEN GREEN RED 8 STROBE LIME ROYAL BLUE FINE GREEN FINE GREEN FINE RED FINE 9 DIMMER SPEED MODE CTO BLUE ROYAL BLUE ROYAL BLUE ORANGE 10 HUE BLUE FINE ROYAL BLUE FINE ROYAL BLU...

Page 22: ...400K 5600K 5600K 5800K 5800K 6000K 6000K 6200K 6200K 6400K 6400K 6600K 6600K 6800K 6800K 7000K 7000K 7200K 7200K 7400K 7400K 7600K 7600K 7800K 7800K 8000K 8000K 8200K 8200K 8400K 8400K 8600K 8600K 880...

Page 23: ...4 ROYAL BLUE FINE 0 100 000 255 000 5 6 7 6 7 9 11 11 15 BLUE 0 100 000 255 000 10 12 12 16 BLUE FINE 0 100 000 255 000 6 7 8 7 8 11 13 13 17 LIME 0 100 000 255 000 12 14 14 18 LIME FINE 0 100 000 255...

Page 24: ...N FILTER FRAME CODE ECLFRSTPG OPTIONAL 2 3 DETAIL 1 Press the pin 1 and the snap will automatically open upwards 2 Insert the gel filter frame 3 into the gel frame lock DETAIL and close down the snap...

Page 25: ...3 2 DETAIL 1 1 Press the pin 1 and the snap will automatically open upwards 2 Insert the barn door 3 into the gel frame lock DETAIL 1 throught the holder assembly of the barn door DETAIL 2 Then close...

Page 26: ...NS CODE ECLFRSNL OPTIONAL 2 3 DETAIL 1 Press the pin 1 and the snap will automatically open upwards 2 Insert the narrow angle lens 3 into the gel frame lock DETAIL and close down the snap NOTE To remo...

Page 27: ...ed personnel It is PROLIGHTS policy to apply the strictest possible calibration procedures and use the best quality materials available to ensure optimum performance and the longest possible component...

Page 28: ...ectors and connect them directly together to bypass one product at a time until normal operation is regained Once found the error have that fixture serviced by a qualified technician Timeout error aft...

Page 29: ...Note...

Page 30: ...Note...

Page 31: ......

Page 32: ...PROLIGHTS is a trademark of MUSIC LIGHTS S r l musiclights it prolights it support prolights it Via A Olivetti snc 04026 Minturno LT ITALY Tel 39 0771 72190...

Reviews: