Keys
Mode
Description
MENU + ENTER then power on
Clear All
Clear all value of fun factory defaul
UP + DOWN after power on
Flip Display
Directly flip display without enter inside menu
ERRROR SHOWED
POSSIBLE CAUSES
[LED TEMPERATURE SENSOR ERROR]
LED temperture sensor damaged (open or in short circuit)
[TEMPERATURE TOO HIGH]
This error message indicates that an overheating has occurred and the led has been
switched OFF by the product protection system.
[MAINTENANCE TIME]
Need to be done standard maintenance and also reset of elapsed time
[DMX ACTIVE]
Transfer configuration is used with dmx signal connected
11 - SHORTCUTS
12 - ERRORS
Parameter
PID
GET SET Values
Description
Default
Value
DMX Fault
0x82DD
x
x
0-2
0: Blackout
1: Hold
2: Standalone Mode
0
Master/Slave
0x8211
x
x
0-2
0: Master DMX
1: Master No DMX
2: Slave
0
Standalone Mode
0x82EC
x
x
0-3
0: Static
1: CCT preset
2: Manual WW/CW
3: FX
1
Static Colors
0x82BE
x
x
0-2
0: Full WW
1: Full CW
2: Full WW+CW
1
White Presets
0x82BF
x
x
0-9
0: 2700K
1: 2800K
2: 3200K
3: 3500K
4: 4000K
5: 4500K
6: 5000K
7: 5600K
8: 6000K
9: 6500K
4
Manual WW
0x82E2
x
x
0 - 255
Set level of WW in Manual WW/
CW mode
255
Manual CW
0x82E3
x
x
0 - 255
Set level of CW in Manual WW/
CW mode
255
FX Selector
x
x
0 - 3
Choose FX 1 - 4
0
FX Speed
x
x
0 - 100
Set speed of FXs
100
Fan Mode
0x82D2
x
x
0 - 3
0: Auto
1: High
2: Silent
3: Off
0
Output Control
0x830C
x
x
0 - 1
0: Dynamic
1: Constant
0
White Calibration - WW
0x82C6
x
x
125 - 255
Calibrate level of WW
---
White Calibration - CW
0x82C7
x
x
125 - 255
Calibrate level of CW
---
Fixture Hours
0x82C5
x
0 - 65535
Show Fixture Hours
---
Power Consumption (AC 220V)
0x82DE
x
Show Power Consumption (W)
---
Maintenance Period (Alert)
0x82DF
x
0 - 300
300
Maintenance Period (Time and Reset)
0x82E0
x
x
0 - 300
---
Error Messages
0x82E0
x
---
Clean All Data
0x82C8
x
x
0 - 1
0: No 1: Yes
0