17 - ERROR MESSAGES
The error is shown on the unit display. In the table below, the "ERROR SHOWED ON SCREEN" column
lists the possible errors, accompanied by a possible cause ("POSSIBLE" CAUSES "column).
The color of the error messages (listed in the "COLOR MESSAGES" column) is different for each board
it refers to ("PCB" column).
On page 39 you can see the location of the various pcb boards.
ERROR SHOWED ON
SCREEN
POSSIBLE CAUSES
POSSIBLE PCB
WITH ANOMALY
[PAN MOTOR ERROR]
This message will appear after the reset of the product if:
2U
the PAN magnetic-indexing circuit detect a failure (sensor
failed or magnet is missing).
2U
or the stepping motor is defective.
2U
or its driving IC on the PCB is defective.
2U
or the product is not located in the default position after the
reset of the fixture.
2U
[PAN LOCKED]
Pan is locked.
2U
[TILT MOTOR ERROR]
This message will appear after the reset of the product if:
2U
the TILT magnetic-indexing circuit detect a failure (sensor
failed or magnet is missing) .
2U
or the stepping motor is defective.
2U
or its driving IC on the PCB is defective.
2U
or the product is not located in the default position after the
reset of the fixture.
2U
[TILT LOCKED]
Tilt is locked.
2U
[PAN ENCODER ERROR]
Pan encoder not detecteld.
2U
[TILT ENCODER ERROR]
Tilt encoder not detecteld.
2U
[PAN ERROR]
Pan sensor not detecteld.
2U
[TILT ERROR]
Tilt sensor not detecteld.
2U
[DISPLAY BATTERY
ERROR]
Recharge The battery on the display board, keeping the
product ON for some hours.
1U
If the error still occurrs, the battery is faulty . Replace the
battery on the display board.
1U
[LED ERROR]
This error message is displayed when the lamp is switched
OFF without a command from the product control system.
3U
[LED TEMPERATURE
ERROR]
This error message indicates that an overheating on the
lamp has occurred and the lamp has been switched OFF by
the product protection system.
3U
[LED TEMP. SENSOR
ERROR]
LAMP sensor damaged (open or in short circuit).
3U