[CYAN ERROR]
Failure detected during the reset of the Cyan flag, if
the Cyan flag of the CMY module is not located in its
default position
Yellow
3U
[GOBO ROTATION ERROR]
Failure detected during the reset of the rotation of the
rotating gobo, if the rotating gobos are not located in
the default positions
Yellow
3U
[STATIC
GOBO
WHEEL
ERROR]
Failure detected during the reset of the static gobo
wheel, if this wheel is not located in the default position
Yellow
3U
[MOTOR PCB 3 ERROR]
Motor pcb 4U not detected
Purple
4U
[FROST ERROR]
Failure detected during the reset of the effect FROST,
if this effect is not located in the default position.
Purple
4U
[4F PRISM ERROR]
Failure detected during the reset of the 4F effect prism,
if this effect is not located in the default position.
Purple
4U
[8F PRISM ERROR]
Failure detected during the reset of the 8F effect prism,
if this effect is not located in the default position.
Purple
4U
[4F
PRISM
ROTATION
ERROR]
Failure detected during the reset of the 4F effect prism
rotation, if this effect is not located in the default
position.
Purple
4U
[8F
PRISM
ROTATION
ERROR]
Failure detected during the reset of the 8F effect prism
rotation, if this effect is not located in the default
position.
Purple
4U
[FOCUS ERROR]
Failure detected during the reset of the FOCUS, if the
focus lens is not located in its default position.
Purple
4U
[ZOOM ERROR]
Failure detected during the reset of the ZOOM system,
if the focus lens is not located in its default position.
Purple
4U
[LAMP AIR IN (LOW) FAN
ERR.]
Air in blower for cooling the lamp failed, the lamp has
been switched OFF.
Purple
4U
[LAMP AIR OUT (UP) FAN
ERR.]
Air out blower for cooling the lamp failed, the lamp
has been switched OFF.
Purple
4U
[SHUTTER 1 ERROR]
Failure detected during the reset of the effect
SHUTTER, if this effect is not located in the default
position.
Purple
4U
[SHUTTER 2 ERROR]
Failure detected during the reset of the effect
SHUTTER, if this effect is not located in the default
position.
Purple
4U
[SPOT FILTER ERROR]
Failure detected during the reset of spot filter, if the
rotating gobos are not located in the default positions Purple
4U
[FAN PCB ERROR]
Fan PCB not detected
Acquamarine
5U
[LAMP RIGHT FAN ERROR]
Right blower for cooling the lamp failed, the lamp has
been switched OFF.
Acquamarine
5U
[LAMP LEFT FAN ERROR]
Left blower for cooling the lamp failed, the lamp has
been switched OFF.
Acquamarine
5U
[LAMP
TEMPERATURE
ERROR]
This error message indicates that an overheating on
the lamp has occurred and the lamp has been switched
OFF by the product protection system.
Acquamarine
5U
[IGNITOR
TEMPERATURE
ERROR]
This error message indicates that an overheating
on the ignitor has occurred and the lamp has been
switched OFF by the product protection system.
Acquamarine
5U
[LAMP
TEMP.
SENSOR
ERROR]
LAMP sensor damaged (open or in short circuit)
Acquamarine
5U
PROLIGHTS - Astra
Hybrid420
33