background image

VW Variant - DMX Chart Summary

 Channel

1CH

2CH

3CH

4CH

9CH

Only M18VW

9CH2

1

Dimmer

Dimmer

Warm White  Dimmer

Dimmer

Dimmer

2

CCT

Cold White

Dimmer Fine Dimmer Fine Strobe 1

3

Dimmer Fade CCT

Strobe

Strobe 2

4

Dimmer Fade CCT

Warm White 

1

5

Crossfade 

from CCT to 

WW/CW

Cold White 1

6

Warm White  Warm White 

2

7

Cold White

Cold White 2

8

Dimmer Fade Dimmer Fade

9

Control

Control

1CH

2CH

3CH

4CH

9CH

Function 

DMX Value

Default

1

1

1

1

DIMMER

Linear from 0% to 100%

000 ÷ 255

000

2

2

DIMMER FINE

000 ÷ 255

000

3

STROBE

Open

Strobe from slow to fast

Open

Pulse in from slow to fast

Open

Pulse out from slow to fast

Open

Random from slow to fast

Open

000 ÷ 001

002 ÷ 062

063 ÷ 064

065 ÷ 125

126 ÷ 127

128 ÷ 188

189 ÷ 190

191 ÷ 251

252 ÷ 255

255

2

3

4

CCT

Linear from 2800K to 6500K

000 ÷ 255

000

5

CROSSFADE from CCT to WW/CW

Linear from 0% to 100%

000 ÷ 255

000

1

6

WARM WHITE

Linear from 0% to 100%

000 ÷ 255

255

2

7

COLD WHITE

Linear from 0% to 100%

000 ÷ 255

255

3

4

8

DIMMER FADE

Read by menu 

Dimmer speed Auto                       

Dimmer speed Fast 

Dimmer speed Medium

 

Dimmer speed Slow

000 ÷ 051 

052 ÷ 101 

102 ÷ 152 

153 ÷ 203 

204 ÷ 255

000

PROLIGHTS - ArcShine 

M series

23

Summary of Contents for ArcShine M9-18VW

Page 1: ...USER MANUAL REV 01 08 22 English version ArcShine M9 18FC ArcShine M9 18VW 9 18x4W IP66 RGB Warm White architectural linear bar 50 100 cm 9 18x4W IP66 Variable White architectural linear bar 50 100 cm ...

Page 2: ...oss occasioned by the use of inability to use or reliance on the information contained in this document Product user manual can be downloaded from the website www prolights it or can be inquired to the official PROLIGHTS distributors of your territory https www prolights it sales_network html Scanning the below QR Code you will access the download area of the product page where you can find a broa...

Page 3: ...TION OF THE DMX TERMINATION 11 DMX ADDRESSING 11 7 RDM FUNCTIONS 12 8 OPERATION VIA DATAMASTER 14 RDM SETTING 14 STAND ALONE FUNCTION 14 9 MENU STRUCTURE 15 10 DMX CHARTS 19 RDM Personality ID List 19 FC Variant DMX Chart Summary 19 RDM Model ID 19 Product Variant 19 ID 19 VW Variant DMX Chart Summary 23 11 ACCESSORIES INSTALLATION 25 LIGHT DIFFUSION FILTER ARCSM18FILTER20 40 60 1060 3060 ARCSM9FI...

Page 4: ...nt requirements of all connected devices Isolate the fixture from power immediately if the power plug or any seal cover cable or other components are damaged defective deformed or showing signs of overheating Do not reapply power until repairs have been completed Refer any service operation not described in this manual to PROLIGHTS Service team or an authorized PROLIGHTS service center Installatio...

Page 5: ...urface of the fixture can reach up to 60 C 140 F during operation Avoid contact with people and materials Maintenance Warning Disconnect the fixture from AC mains power and allow to cool for at least 10 minutes before handling Only technicians who are authorized by PROLIGHTS or Authorised service partners are permitted to open the fixture Users may carry out external cleaning following the warning...

Page 6: ...h UL 1573 CSA C22 2 No 166 Stage and Studio Luminaires and Connector Strips UL 1012 CSA C22 2 No 107 1 Standard for power units other than class 2 FCC Compliance This device complies with Part 15 of the FCC Rules Operation is subject to the fol lowing two conditions 1 This device may not cause harmful interference and 2 This device must accept any interference received including interference that ...

Page 7: ...aCON M 20m ARCS9FIXBD barndoor to adjust the light beam for ARCSHINES9 and ARCSHINEM9 ARCS18FIXBD barndoor to adjust the light beam for ARCSHINES18 and ARCSHINEM18 ARCSM9FILTER20 light diffusion filter for ARCSHINEM9 20 ARCSM9FILTER40 light diffusion filter for ARCSHINEM9 40 ARCSM9FILTER60 light diffusion filter for ARCSHINEM9 60 ARCSM9FILTER1060 light diffusion filter for ARCSHINEM9 10 x60 ARCSM9...

Page 8: ...2 in ARCSHINEM9 weight 3 kg 6 61 lbs 1001 mm 39 4 in 71 mm 2 8 in 106 mm 4 2 in 106 mm 4 2 in 106 mm 4 2 in 71 mm 2 8 in ARCSHINEM18 weight 4 9 kg 10 80 lbs 155 mm 6 1 in 601 mm 23 7 in 121 mm 4 8 in ARCSSM9OUTERCASE weight 5 kg 11 02 lbs 155 mm 6 1 in 1101 mm 43 3 in 121 mm 4 8 in ARCSSM18OUTERCASE weight 10 kg 22 04 lbs Fig 01 ...

Page 9: ... When suspending the fixture above ground level secure it against failure of primary attachments by attaching a safety wire that is approved as a safety attachment for the weight of the fixture to an anchor point on the product main frame Do not use removable parts or weak anchors for secondary attachment Warning When clamping the fixture to a truss or other structure at any angle use clamps of ha...

Page 10: ...for connection to the Mains 100 240V 50 60Hz 2 DMX IN 4 p XLR 1 GND 2 sign 3 sign 4 N C 3 DMX OUT 4 p XLR 1 GND 2 sign 3 sign 4 N C 4 POWER OUT power output for connection of multiple units in series 5 BRACKET for fastening 6 GORE VALVE 7 SAFETY EYE to attach safety cable Fig 03 ...

Page 11: ...d with auto switching power supply that automatically adjusts to any 50 60Hz AC power source from 100 240 Volts If you need to install a power plug on the power cable to allow connection to power outlets install a grounding type earthed plug following the plug manufacturer s instructions If you have any doubts about proper installation consult a qualified electrician The max power consumption is 4...

Page 12: ...t the unit to your DMX network it is necessary to use the adapters XLR 5 pin IP67 signal connector supplied with this product CONNECTION DAISY CHAIN OF THE DMX LINE Connect the DMX data output from the DMX source to the product DMX input male connector Run the data link from the product DMX output female connector connector to the DMX input of the next fixture Terminate the data link by connecting...

Page 13: ... be executing the same behaviour Selecting the same address to multiple fixtures can be useful for diagnostic purposes and symmetrical control DMX addressing is limited to make it impossible to set the DMX address so high that you are left with out enough control channels for the product To set the fixture s DMX address 1 Press ENTER to open the main menu 2 Reach the addressing menu then select th...

Page 14: ...x x CURVE_DESCRIPTION 0x0344 x x OUTPUT_RESPONSE_TIME 0x0345 x x OUTPUT_RESPONSE_TIME_ DESCRIPTION 0x0346 x MODULATION_FREQUENCY 0x0347 x x MODULATION_FREQUENCY_ DESCRIPTION 0x0348 x Sensors SENSOR_DEFINITION 0x0200 x SENSOR_VALUE 0x0201 x x RECORD_SENSORS 0x0202 x BURN_IN 0x0440 x x PROLIGHTS ArcShine M series 12 7 RDM FUNCTIONS The product can communicate using RDM Remote Device Management proto...

Page 15: ...POWER_CYCLES 0x0405 x x Control IDENTIFY_DEVICE 0x1000 x x RESET_DEVICE 0x1001 x POWER_STATE 0x1010 x x PERFORM_SELFTEST 0x1020 x x SELF_TEST_DESCRIPTION 0x1021 x CAPTURE_PRESET 0x1030 x x PRESET_PLAYBACK 0x1031 x x IDENTIFY_MODE 0x1040 x x PRESET_INFO 0x1041 x PRESET_STATUS 0x1042 x x PRESET_MERGEMODE 0x1043 x x POWER_ON_SELF_TEST 0x1044 x x PROLIGHTS ArcShine M series 13 ...

Page 16: ...al product Important The DATAMASTER must be used to configure this product MUSIC LIGHTS suggests that you connect no more than 11 units in this mode and keep the total distance to less than 60 m 197 ft Otherwise you might need to use an RDM optically isolated signal amplifier RDM SETTING To set the RDM functions with the DATAMASTER follow these steps Turn on the DATAMASTER Select the RDM function ...

Page 17: ...the dimmer curve 1 S CURVE 2 SQUARE LAW 3 INVERSE SQUARE LAW 4 OUTPUT_RESPONSE_TIME 0 AUTO To choose the dimmer speed 1 FAST 2 MEDUIM 3 SLOW 5 MODULATION_FREQUENCY 0 600Hz Select PWM frequency 1 1200Hz 2 2000Hz 3 4000Hz 4 6000Hz 5 25kHZ SPECIAL PIDs 1 DMX FAULT 0 BLACKOUT To choose the behaviour of fixture in case of dmx signal lost 1 HOLD 2 STAND ALONE 2 MASTER SLAVE 0 MST DMX Outputs dmx signal ...

Page 18: ...FFECTS SPEED 0 255 Choose speed of the effects 7 STATIC COLORS 0 14 To choose between static color presets 0 R 1 G 2 B 3 W 4 GB 5 RB 6 RG 7 RGB 8 RW 9 GW 10 BW 11 RGW 12 RBW 13 GBW 14 RGBW 8 WHITE PRESETS 0 20 To choose between cct white preset 0 2800K 1 3000K 2 3200K 3 3400K 4 3600K 5 3800K 6 4000K 7 4200K 8 4400K 9 4600K 10 4800K 11 5000K 12 5200K 13 5400K 14 5600K 15 6000K 16 6500K 17 7000K 18 ...

Page 19: ...s fixture hours 25 POWER CONSUMPTION AC 220V Shows fixture s power consumption 26 MAINTENANCE TIME ALERT PERIOD 10 300 To set maintenance time alert period 27 MAINTENANCE TIME ELAPSED TIME 00 ALERT PERIOD Shows elapsed tiime to alert period 28 ERROR MESSAGES Shows error codes 29 CLEAN ALL DATA 0 NO Complete reset of the fixture 1 YES SPECIAL PIDs for VW version 1 DMX FAULT 0 BLACKOUT To choose the...

Page 20: ...color intensity 12 WHITE CALIBRATION WHITE 125 255 Max value of white color intensity 13 INVERT MAPPING x18 version only 0 OFF 1 ON Rotate Section direction 14 CURRENT HOURS 00000 65535 Shows fixture hours 15 POWER CONSUMPTION AC 220V Shows fixture s power consumption 16 MAINTENANCE TIME ALERT PERIOD 10 300 To set maintenance time alert period 17 MAINTENANCE TIME ELAPSED TIME 00 ALERT PERIOD Shows...

Page 21: ...trobe Strobe Blue 1 8 Dimmer Fade Color Macro White 1 9 Control Effects Red 2 10 Effects Speed Green 2 11 Control Blue 2 12 Dimmer Fade White 2 13 Control 14 Dimmer Fade 10 DMX CHARTS RDM Personality ID List ID FC Variant Mode VW Variant Mode 1 1CH 1CH 2 2CH 2CH 3 5CH 3CH 4 9CH 4CH 5 12CH 9CH available only on M18 variant 6 14CH 9CH2 RDM Model ID Product Variant ID ARSCHINEM18FC 0xD089 ARSCHINEM18...

Page 22: ...ng Daylight Blue Flame Red Bastard Amber Deep Orange Pale Gold Apricot Bright Blue Primary Green Special Lavender Pale Lavender Deep Golden Amber Medium Blue Bright Pink Mauve Dark Green Lee Green Dark Blue Light Blue Steel Blue Medium Blue Green Peacock Blue Magenta Dark Pink Middle Rose Light Salmon English Rose Light Rose Orange Deep Amber Straw Light Amber Spring Yellow Dark Yellow Green Just ...

Page 23: ...3 254 255 000 9 11 CONTROL FC versions No Function Safe DIMMER CURVE LINEAR DIMMER CURVE S CURVE DIMMER CURVE SQUARE LAW DIMMER CURVE INVERSE SQUARE LAW DIMMER SPEED AUTO DIMMER SPEED FAST DIMMER SPEED MEDIUM DIMMER SPEED SLOW LED FREQUENCY 600HZ LED FREQUENCY 1200HZ LED FREQUENCY 2000HZ LED FREQUENCY 4000HZ LED FREQUENCY 6000HZ LED FREQUENCY 25KHZ DMX FAULT HOLD DMX FAULT BLACKOUT DMX FAULT STAND...

Page 24: ... from slow to fast Open 000 001 002 062 063 064 065 125 126 127 128 188 189 190 191 251 252 255 255 4 STROBE 2 Refer to STROBE 1 channel for ranges 5 RED 1 Linear from 0 to 100 000 255 255 6 GREEN 1 Linear from 0 to 100 000 255 255 7 BLUE 1 Linear from 0 to 100 000 255 255 8 WHITE 1 Linear from 0 to 100 000 255 255 9 RED 2 Linear from 0 to 100 000 255 255 10 GREEN 2 Linear from 0 to 100 000 255 25...

Page 25: ...0 to 100 000 255 000 2 2 DIMMER FINE 000 255 000 3 STROBE Open Strobe from slow to fast Open Pulse in from slow to fast Open Pulse out from slow to fast Open Random from slow to fast Open 000 001 002 062 063 064 065 125 126 127 128 188 189 190 191 251 252 255 255 2 3 4 CCT Linear from 2800K to 6500K 000 255 000 5 CROSSFADE from CCT to WW CW Linear from 0 to 100 000 255 000 1 6 WARM WHITE Linear fr...

Page 26: ...025 026 027 028 029 030 031 032 033 034 035 036 037 038 039 040 041 042 043 044 045 046 047 048 049 050 051 052 053 054 253 254 255 000 14CH Function DMX Value Default 1 DIMMER Linear from 0 to 100 000 255 000 2 STROBE 1 Open Strobe from slow to fast Open Pulse in from slow to fast Open Pulse out from slow to fast Open Random from slow to fast Open 000 001 002 062 063 064 065 125 126 127 128 188 1...

Page 27: ...FI TER20 40 60 1060 3060 OPTIONAL 1 A B C Loosen and remove the marked four screws A on one side only Then remove the side cover B and the plastic ring C 2 A A B Insert the light diffusion filter accessory A into the housing hardware guide B Then reassemble the plastic ring side cover and the four screws see fig 1 Fig 09 ...

Page 28: ...e cover B and plastic ring C 2 C C A C C D B Insert the barndoor accessory A into the housing hardware guide B Then mount the three marked screws C into the holes provided on the barndoor hardware D and reassemble the plastic ring side cover and the four screws see fig 1 Fig 10 BARNDOOR ARCS18FIXBD ARCS9FIXBD OPTIONAL ...

Page 29: ...ll other service operations on the product must be carried out by PROLIGHTS its approved service agents or trained and qualified personnel It is PROLIGHTS policy to apply the strictest possible calibration procedures and use the best quality materials available to ensure optimum performance and the longest possible component lifetimes However optical components are subject to wear and tear over th...

Page 30: ...nectors and connect them directly together to bypass one product at a time until normal operation is regained Once found the error have that fixture serviced by a qualified technician Timeout error after fixture reset One or more hardware components requires mechanical adjustments Check product stored error messages for more information Contact PROLIGHTS Service or an authorized service partner Me...

Page 31: ......

Page 32: ...PROLIGHTS is a trademark of MUSIC LIGHTS S r l musiclights it prolights it support prolights it Via A Olivetti snc 04026 Minturno LT ITALY Tel 39 0771 72190 ...

Reviews: