Following  are  a  few  common  problems  that  may  occur 
during  operation  and  some  suggestions  for  easy 
troubleshooting: 
 
A. The unit does not work, no light and the fan does not work 

1.

 

Check the connection of the power and the main fuse. 

 

B. Not responding to DMX controller 

1.

 

DMX LED should be on. If not, check DMX cables to see if linked 
correctly. 

2.

 

If the DMX address is showing but no response to the controller, 
check the address settings and DMX polarity. 

3.

 

Try another DMX controller.     

 
C. No response to the sound 

1.

 

Make sure the unit is not receiving a DMX signal. 

2.

 

Check  the  microphone  to  see  if  it  is  good  by  tapping  it.  The 

microphone is located on the bottom plate of the unit. 

 

5. Fixture Cleaning   

The  cleaning  of  external  optical  lenses  must  be  carried  out 
periodically to optimize light output. Cleaning frequency depends on 
the  environment  in  which  the  fixture  operates:  damp,  smoky  or 
particularly dirty surrounding can cause a greater accumulation of 
dirt on the unit’s optics. 

Clean  with  a  soft  cloth  using  normal  glass  cleaning  fluid  or  mild 
soapy water. 

Ÿ

 

Always dry the parts carefully. 

Ÿ

 

Clean the external optics at least every 20 days. 

 

 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for EQLED052

Page 1: ...EQUINOX FUSION SCAN MAX User Manual EQLED052 Contents 1 Safety Instructions 2 Features Specifications 3 How To Set The Unit 4 Troubleshooting 5 Fixture Cleaning...

Page 2: ...cables during operation as the high voltage may cause an electric shock Warning To prevent or reduce the risk of electrical shock or fire do not expose the unit to rain or moisture Do not open the uni...

Page 3: ...R button and the display will blink Use the DOWN and UP buttons to change the mode Once the required mode has been selected press the ENTER button to confirm To go back to the functions without any ch...

Page 4: ...e Press the MENU button to select Press the ENTER button and the display will blink Use the DOWN and UP buttons to select the Slave 1 Slave 2 or Master mode Once the mode has been selected press the E...

Page 5: ...Press the MENU button to select Press the ENTER button and the display will blink Use the DOWN and UP buttons to select the normal or pan inversion mode Once the mode has been selected press the ENTE...

Page 6: ...eans the unit works normally and Slave 2 means 2 light show In order to create a great light show you can set Slave 2 on the second unit to get contrast movement to each other even if you have two uni...

Page 7: ...Setting 1 Pan1 000 255 Pan 0 540 2 Pan Fine 000 255 Tilt 0 270 3 Tilt 000 255 0 100 4 Tilt Fine 000 255 0 100 5 6 Gobo 000 007 008 015 016 023 024 031 032 039 040 047 048 055 056 063 064 071 072 079 0...

Page 8: ...controller C No response to the sound 1 Make sure the unit is not receiving a DMX signal 2 Check the microphone to see if it is good by tapping it The microphone is located on the bottom plate of the...

Page 9: ...www prolight co uk...

Reviews: