Montageanleitung /
Installation manual
MBN GmbH
Balthasar-Schaller-Str. 3
86316 Friedberg
Germany
www.proled.com
AUSWAHL DER LED-BESTROMUNG
1
2
3
Iout
(mA)
Pout
(W)
Uout
(V)
OFF OFF OFF 1050 15 – 45
25 – 70
ON OFF OFF 1150 16 – 45
25 – 70
OFF ON OFF 1200 17 – 45
25 – 70
ON
ON OFF 1300 18 – 45
25 – 64
ON OFF ON
1400 20 – 45
25 – 56
OFF ON
ON
1500 21 – 45
25 – 50
ON
ON
ON
1600 22 – 45
21 – 43
L523M04DA1
1
2
3
Iout
(mA)
Pout
(W)
Uout
(V)
OFF OFF OFF 1050 15 – 45
14 – 43
ON OFF OFF 1150 16 – 45
14 – 39
OFF ON OFF 1200 17 – 45
14 – 38
ON
ON OFF 1300 18 – 45
14 – 35
ON OFF ON
1400 20 – 45
14 – 32
OFF ON
ON
1500 21 – 45
14 – 30
ON
ON
ON
1600 22 – 45
14 – 28
L523M04DA2
1
2
3
Iout
(mA)
Pout
(W)
Uout
(V)
OFF OFF OFF 1050 26 – 75
25 – 71
ON OFF OFF 1150 29 – 75
25 – 65
OFF ON OFF 1200 30 – 75
25 – 62
ON
ON OFF 1300 33 – 75
25 – 58
ON OFF ON
1400 35 – 75
25 – 53
OFF ON
ON
1500 38 – 75
25 – 50
ON
ON
ON
1600
37 - 75
23 – 47
L523M07DA
BEDIENUNG
PUSH-DIM:
AN/AUS: kurzes Drücken (<1 s)
Stufenloses Dimmen: langes Drücken (>1 s)
Mit jedem erneutem langem Drücken verläuft das Dimmen in die entgegengesetzte Richtung
Bei Ein- und Ausschalten wird die letzte Einstellung beibehalten, auch im Falle eines Stromausfalles.
SYNCHRONISATION BEI PUSH-DIM:
Sollten Leuchten unterschiedliche Dimmung haben oder in verschiedenen Richtungen dimmen, kann
das durch eine Synchronisierung behoben werden.
Zum Synchronisieren muß der Schalter lange (>15 s) gedrückt werden. Hierzu zuerst durch kurzes
Drücken alle Leuchten ausschalten und durch langes Drücken synchronisieren. Alle
zusammenhängende Leuchten dimmen auf 50%.
PERMANENT-SPEICHER:
Das Netzteil ist mit einem Permanentspeicher ausgestattet. Dieser setzt, bei erneutem Vorliegen der
Spannung nach Stromausfall, die Leuchte auf den zuletzt eingestellten Wert.
DALI DIMMKURVE:
06.21 Technische Änderungen vorbehalten
D
A
LI
WER
T
DIMMUNG