Part Number 560361-020 Issue 1.0 November 2012.
10 of 13
2
Operation - override
When the system is in a overload condition certain equipment motions will be disabled. Condition No 4 shown on the previous page has
all motions disabled. To allow the machine to be moved to a safe position the motion control can be cancelled. To override the system
press the MODE button. The red LED and the internal and external alarms will still operate, but hydraulic control will be released. The
system will automatically cancel the override function when the machine reaches a safe position.
2
Operation - low pressure
The measurement of hydraulic oil pressure
in the boom lift cylinder is crucial to the
operation of the RCI. In the event of low
pressure being detected the message
shown here will appear, the amber LED will
illuminate, and the internal alarm will sound.
This condition can be ignored it the
equipment is resting on the ground as low
pressure under this circumstance is normal.