561383-002 Issue 1.1
23
Max hgt = 5.46m
[ENTER] to SET
In this example the maximum equipment height
is referred to the bucket pin.
<<<<LIMIT>>>>
! ARM TOO HIGH
PRESS
[ENTER]
The system will be in alarm mode
until the equipment is lowered
from the SET height. The VAR
lamp will now be lit.
6.1.0 Setting the height limit at an operator derived equipment position - Continued
The Height monitoring mode is now active, any piece of equipment which intrudes into the set Height Limit will cause the
relevant alarm and motion cut condition to occur. Variable height limit is not active with key switch in 3.7m or 4.7m positions.
The display will show the current
height, move the equipment to the
desired new maximum height.
Press [ENTER] to
set height limit
The system will return to the
height setting screen if the
machine is not in an alarm
condition or if the equipment is
lowered out of an alarm condition.
Maximum
Equipment Height
= 5.46m